Completed Inspections

Permit Status:
Permit Number:
Permit Description:
Total Completed Inspections - 6
Date Description Inspector Results Comments
09/28/1999 PDSD Site/Engineering Division - Landscaping Passed {Activity date: 09/28/1999; Status: APPR; Inspector: JONEILL; Comment: Entered by JVOGELSB - APPROVED} ; {Activity date: 11/16/1998; Status: Correction Required; Inspector: PTHOMAS; Comment: Entered by JVOGELSB - CORRECTION REQUIRED}
06/07/2000 PDSD Site/Engineering Division - NPPO Passed {Activity date: 09/28/1999; Status: Correction Required; Inspector: JONEILL; Comment: Entered by JVOGELSB - CORRECTION REQUIRED} ; {Activity date: 11/16/1998; Status: Correction Required; Inspector: PTHOMAS; Comment: Entered by JVOGELSB - CORRECTION REQUIRED}
09/19/2005 COT - WATR - Design Plan Construction Passed {Activity date: 09/19/2005; Status: Approved; Inspector: LHERNAND; Comment: Entered by JFEMLIN1 - Water approved}
09/26/2007 SPECIAL INSPECTION - OTHER (Third Party) Passed {Activity date: 09/26/2007; Status: Approved; Inspector: SRAVAL; Comment: Entered by THAUSER1 - G-1999-125}
04/07/2021 TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance) Passed {Activity date: 04/07/2021; Status: Approved; Inspector: RL; Comment: Entered by RLEIGH1 - } ; {Activity date: 02/28/2018; Status: Denied; Inspector: TOM; Comment: Entered by DROBERT5 - From: Tom Adkins <Tom.Adkins@tucsonaz.gov>
To: David Roberts <David.Roberts@tucsonaz.gov>
Cc: David Stiffey <David.Stiffey@tucsonaz.gov>, Richard Leigh <Richard.Leigh@tucsonaz.gov>
Bcc:
Date: Fri, 23 Feb 2018 09:30:30 -0700
Subject: Daystar Estates

Dave,
Per your request, I inspected the subject PIA project to check for compliance with TDOT standards for final acceptance and found the following issues:
1. Asphalt has shrinkage cracks throughout project that need sealing on both Mariah Joy Place and Treighton Jon Place.
2. Sidewalk from approx. Lot 17 to Lot 13 is not compliant with ADA requirements for cross slope.
3. Blue RPM needed at fire hydrant adjacent to Lot 21.
4. Lots 11 & 12 have no expansion joint at driveways.
5. Private retaining wall at Lot 9 is about 1' inside of Right of Way
6. Lot 21 has a heaved portion of sidewalk causing trip hazard.
7. Blue RPM needed at fire hydrant adjacent to Lot 6. Hydrant valve in street needs concrete collar.
8. Concrete spillway adjacent to Lot 8 was built with gabions. This was not as-built on the plan.
9. Barricade railing across subject spillway was not installed as per plan requirements.
Please let me know if I can be of further assistance,}
07/13/2001 COT - ENGR - Site - Assurance Release Passed