Permit: TD-DEV-0924-00245
Permit Details
Status:
Inspections
Type:
Development Package
Address:
8300 E VALENCIA RD
Address NEW:
8300 E VALENCIA RD
Apply Date:
09/03/2024
Applicant:
Chris Guinter
Description:
Revision 1 - Submitted 10.09.25 corrections, water update; New buildingS with parking and landscaping improvements
Permit Reviews
Permit Number - TD-DEV-0924-00245
Permit Status: Inspections
Permit Description: Revision 1 - Submitted 10.09.25 corrections, water update; New buildingS with parking and landscaping improvements
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/09/2024 | DEVELOPMENT PACKAGE NEW v.1 | 10/14/2024 | REQUIRES RESUBMIT |
| 12/09/2024 | DEVELOPMENT PACKAGE NEW v.2 | 01/30/2025 | REQUIRES RESUBMIT |
| 01/30/2025 | DEVELOPMENT PACKAGE NEW v.3 | 01/31/2025 | APPROVED |
| 10/09/2025 | DEVELOPMENT PACKAGE NEW REVISION v.1 | 11/05/2025 | REQUIRES RESUBMIT |
| 11/06/2025 | DEVELOPMENT PACKAGE NEW REVISION v.2 | 11/07/2025 | APPROVED |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TD-DEV-0924-00245
Permite Description: Revision 1 - Submitted 10.09.25 corrections, water update; New buildingS with parking and landscaping improvements
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/25/2026 | N/A | Partial Pass | Compaction tests comply for Subgrade at BLDG's and Refuse Enclosures. Compaction tests for paved areas will be later. Basins are cut and look correct. Contours are correct except east of building 23 needs to come up so drainage goes to valley gutter. Spot grades are good. Swale may need to be cut to Water havesting area at SW from bldg 24 and 25 if intension is for roof drainage to go to that basin. | |
| 10/07/2026 | N/A | Partial Pass | 5 curb islands PAG 209 vert curbs okay to pour. | |
| 10/12/2026 | For trash and recycling enclosures | N/A | Partial Pass | Bollards and SOG reinforcement correct. okay to pour SOG’s |
| 10/21/2026 | N/A | Partial Pass | Okay to grout retaining wall on west side of parking lots. Water proofing on back side will get second coat. Vibrate all grout. |
Completed Inspections
Permit Status: Inspections
Permit Number: TD-DEV-0924-00245
Permit Description: Revision 1 - Submitted 10.09.25 corrections, water update; New buildingS with parking and landscaping improvements
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2025 | NPPO Pre-Construction | Passed | from the contractor that we needed to have all the test results all the material that has been used on site had to call him every two weeks for the sweep inspection | |
| 11/20/2025 | PDSD Engineering Division Pre-Construction SITE | Passed | inform the contractor, we need to have all material, tested and call for swapp inspection every two weeks |