Permit: TD-DEV-0723-00296
Permit Details
Apply Date:
07/05/2023
Applicant:
Description:
Site Development Package for new Indoor Storage Facility
Permit Reviews
Permit Number - TD-DEV-0723-00296
Permit Status: Complete
Permit Description: Site Development Package for new Indoor Storage Facility
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/12/2023 | DEVELOPMENT PACKAGE NEW v.3 | 01/16/2024 | APPROVED |
| 06/25/2024 | DEVELOPMENT PACKAGE NEW v.4 | 07/24/2024 | REQUIRES RESUBMIT |
| 09/12/2024 | DEVELOPMENT PACKAGE NEW v.5 | 09/18/2024 | APPROVED |
| 08/24/2023 | DEVELOPMENT PACKAGE NEW v.2 | 09/27/2023 | REQUIRES RESUBMIT |
| 07/06/2023 | DEVELOPMENT PACKAGE NEW v.1 | 07/10/2023 | REQUIRES RESUBMIT |
Outstanding Inspections
Permit Status: Complete
Permit Number: TD-DEV-0723-00296
Permite Description: Site Development Package for new Indoor Storage Facility
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/29/2024 | ENGR - Drainage Structures | N/A | Partial Pass | Contractors forming up catch basins one on the west side one on the east side and they are going to form up some head walls on the north end of the project. Josh Garcia inspected the 32 inch RCP pipe off of the catch basins. |
| 01/22/2025 | COT - ENGR - Stormwater | N/A | Complete (Recurring) | I informed the contractor that they need to put riprap at the bottom of that 32 inch storm drain pipe and backfill the wing walls |
| 05/22/2025 | SITE | N/A | Partial Pass | I discussed with GC Nick Herndon that WHIAs Subgrade should by roughly 9” below adjacent pavement in larger WHIAs so that after DG goes down the WHIA bottoms will be about 6” below pavement. They look good in shape and in relation to BC. Some areas need to be lowered still. He plans on Hydroseeding trail easement area. |
| 06/05/2025 | For trash and recycling enclosures | N/A | Partial Pass | Contractor call in for the floor for the trash enclosures good to pour. |
Completed Inspections
Permit Status: Complete
Permit Number: TD-DEV-0723-00296
Permit Description: Site Development Package for new Indoor Storage Facility
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/30/2024 | PDSD Engineering Division Pre-Construction SITE | Passed | I advised the contractor to call in every two weeks for swept and call Lynn as needed for inspections. Today they’re going to pour to catch basins the one on the west side of the building and one on the east side of the building. Contractor will call me when they head walls are ready to be inspected. | |
| 02/13/2025 | SITE - Stormwater Setup and Controls | Passed | ||
| 04/30/2025 | SITE - Stormwater Follow-up | Passed | ||
| 07/23/2025 | Final inspection to ensure all landscape and water harvesting SITE | Passed | ||
| 07/23/2025 | For trash and recycling enclosures | Passed | ||
| 07/23/2025 | SITE - Stormwater Final Inspection | Passed | ||
| 07/30/2025 | ENGR Engineering Final | Passed |