Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Development Package
Address NEW:
4061 E MONTE VISTA DR
Apply Date:
06/09/2024
Applicant:
David Evans
Description:
Multifamily development

Permit Reviews

Permit Number - TD-DEV-0624-00172
Permit Status: Inspections
Permit Description: Multifamily development
Start Date Submittal Complete Date Status  
09/27/2024 DEVELOPMENT PACKAGE NEW v.3 09/27/2024 REQUIRES RESUBMIT Review Details
06/10/2024 DEVELOPMENT PACKAGE NEW v.1 07/17/2024 REQUIRES RESUBMIT Review Details
08/02/2024 DEVELOPMENT PACKAGE NEW v.2 09/05/2024 REQUIRES RESUBMIT Review Details
10/31/2024 DEVELOPMENT PACKAGE NEW v.5 10/31/2024 APPROVED Review Details
09/27/2024 DEVELOPMENT PACKAGE NEW v.4 10/30/2024 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TD-DEV-0624-00172
Permit Status: Inspections
Permit Description: Multifamily development
Total Outstanding Activity Conditions - 1
Date Name
10/02/2025 CRWHPLAN NEEDS TO BE CREATED PRIOR TO CLOSEOUT

Outstanding Inspections

Permit Status: Inspections
Permit Number: TD-DEV-0624-00172
Permite Description: Multifamily development
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
07/30/2025 N/A Failed Sidewalks and steps into units have created a trip step condition. A 1" to 1-1/2" step that is not allowed by code.
08/05/2025 For trash and recycling enclosures N/A Failed 08/05/25, Bollards are still too short, the way the forms are set they suggest a possible monolithic pour where bollards, footing and slab are poured all at one time. If this is correct then the rebar mat for the slab is missing. There should be a 12"x 12" with #4 rebar that creates the mat and the footing should be tied into that as well. It is strongly suggested to run the water lines under the footing by means of a sleeve. Right now there is not enough clearance to the sleeve and ground and the strength of the footing will be impacted. The left side form seams to be too close to the vertical rebar to be able to set the CMU in the correct placement.
08/22/2025 ENGR Paving N/A Partial Pass Compaction results have been met on both sub grade and AB. Good to pave.

Completed Inspections

Permit Status: Inspections
Permit Number: TD-DEV-0624-00172
Permit Description: Multifamily development
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/13/2024 PDSD Engineering Division Pre-Construction SITE Passed Plants are identified properly, nursery location tbd.
10/10/2025 ENGR Engineering Final Passed
10/10/2025 LAND Landscape Appearance & Function Final Passed

Documents

File Name Document Type  
2_DEVELOPMENT PLAN PACKAGE FOR 4061 E. MONTE VISTA DR._V1.PDF DOCUMENTS VIEW
2_DRAINAGE REPORT FOR 4601 E MONTE VISTA_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW