Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Development Package
Address NEW:
3201 E PRESIDIO RD
Apply Date:
04/16/2025
Applicant:
Amy Cotner
Description:
Restricted record - Expansion to the existing Sanctuary

Permit Reviews

Permit Number - TD-DEV-0425-00119
Permit Status: Inspections
Permit Description: Restricted record - Expansion to the existing Sanctuary
Start Date Submittal Complete Date Status  
04/18/2025 DEVELOPMENT PACKAGE NEW v.1 05/28/2025 REQUIRES RESUBMIT Review Details
11/26/2025 DEVELOPMENT PACKAGE NEW v.2 12/22/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TD-DEV-0425-00119
Permit Status: Inspections
Permit Description: Restricted record - Expansion to the existing Sanctuary
Total Outstanding Activity Conditions - 1
Date Name
12/19/2025 CRWHPLAN NEEDS TO BE CREATED PRIOR TO CLOSEOUT

Outstanding Inspections

Permit Status: Inspections
Permit Number: TD-DEV-0425-00119
Permite Description: Restricted record - Expansion to the existing Sanctuary
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/06/2026 Grading Progress ENGR N/A Partial Pass -Basin 1 is being excavated and will be scarified. Progress good, per plan. But it is not complete. Bottom is to be 2.1 ft and flat with basin top sloped at 3:1. Do not compact basin bottom.
-Area to west that will be new parking has been demoed and subgrade to be scarified and compacted to 95%. When subgrade elevations per plan and is ready for 3" over 6" heavy duty paving per plan, reschedule grading inspection or paving inspection. Schedule flatwork inspection prior to pouring curb/sidewalk.

Completed Inspections

Permit Status: Inspections
Permit Number: TD-DEV-0425-00119
Permit Description: Restricted record - Expansion to the existing Sanctuary
Total Completed Inspections - 2
Date Description Inspector Results Comments
09/01/2026 PDSD Engineering Division Pre-Construction SITE Passed Treat site as if it had a SWPPP plan
Flat work/sidewalk inspection
-paving inspections
-landscape irrigation
-landscape function and appearance final
-Wall inspections for footer of and pre-grout of wall
-site consultation.
Any keynotes and details that I forgot give me a call to check if inspections is necessary.
Contractor will be getting utility permit extended and right of way permit
10/06/2026 Passed -Basin 1 is being excavated and will be scarified. Progress good, per plan. But it is not complete. Bottom is to be 2.1 ft and flat with basin top sloped at 3:1. Do not compact basin bottom.
-Area to west that will be new parking has been demoed and subgrade to be scarified and compacted to 95%. When subgrade elevations per plan and is ready for 3" over 6" heavy duty paving per plan. Reschedule grading inspection or paving inspection. Schedule flatwork inspection prior to pouring curb/sidewalk.