Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Development Package
Address NEW:
8181 S CAMINO DE CAFE
Apply Date:
04/10/2023
Applicant:
Chris Guinter
Description:
New building with parking and landscaping improvements

Permit Reviews

Permit Number - TD-DEV-0423-00208
Permit Status: Issued
Permit Description: New building with parking and landscaping improvements
Start Date Submittal Complete Date Status  
06/20/2023 DEVELOPMENT PACKAGE NEW v.1 07/19/2023 REQUIRES RESUBMIT Review Details
07/19/2023 DEVELOPMENT PACKAGE NEW v.2 12/28/2023 APPROVED Review Details
04/11/2023 DEVELOPMENT PACKAGE REVIEW v.1 06/06/2023 REQUIRES RESUBMIT Review Details
05/06/2026 AS-BUILT v.1 05/14/2026 APPROVED Review Details

Outstanding Inspections

Permit Status: Issued
Permit Number: TD-DEV-0423-00208
Permite Description: New building with parking and landscaping improvements
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
01/09/2026 For trash and recycling enclosures N/A Partial Pass 01/09/26
Wall built to 6' -Reinforcement correct. At end of walls and columns contractor is grouting embed plates from footer to top, just in the first cells that plates are embedded. the rest of wall has 1st lift grouted already. Rebar here will be wet set all the way down. Weep holes punched at bottom of these cells and contractor will send pictures of grout coming out of weep holes for each Refuse Enclosure. OK to grout second lift and embed plates. Vibrate allreinforce cells.

Completed Inspections

Permit Status: Issued
Permit Number: TD-DEV-0423-00208
Permit Description: New building with parking and landscaping improvements
Total Completed Inspections - 10
Date Description Inspector Results Comments
02/21/2024 PDSD Engineering Division Pre-Construction SITE Passed inform the contractor to call Ian inspection for SWPPP every two weeks. Contractor has installed the track out rocks and the wattles
01/12/2026 Passed 01/16/25
Benchmarks are marked on fence post for each site at Camino de Café. Each address was surveyed and rough graded to survey and plan.
Parking area and PAAL are rough cut grade hubs were placed for grading but PAAL and parking area will be rolled and finished before density testing and blue tops are placed on subgrade. Basins are not cut/complete yet from each building down to Camino Café and then in the front along Camino Café. patients can be checked at intermediate or gading final final.
02/19/2026 Passed
04/07/2026 ENGR Paving Passed
04/07/2026 Passed
04/13/2026 COT - ENGR - Signage Final Passed
04/13/2026 For trash and recycling enclosures Passed
05/12/2026 PDSD Site/Engineering Division - Landscaping Passed
05/12/2026 ENGR - Drainage Structures Passed Riprap inlets at curb cuts all in place correct and drainage basins/channels look good.
05/20/2026 ENGR Engineering Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
TD-DEV-0423-00208 - AS-BUILT_V1.PDF DOCUMENTS VIEW
TD-DEV-0423-00208 - DP LOT 12 AS-BUILT LETTER_V1.PDF DOCUMENTS VIEW
2_TD-DEV-0423-00208 - DP SET_V2.PDF DOCUMENTS VIEW
3_TD-DEV-0423-00208 - BR LOT 12 2ND SUBMITTAL RESPONSE_V2.PDF DOCUMENTS VIEW
APPROVED 3_TD-DEV-0423-00208 - DP SET_V3.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
1_ LOT 12 NPPO EXCEPTION SET_V1.PDF DOCUMENTS VIEW
1_BROWN-RITA LOTS 8-12_ DRAINAGE REPORT_V1.PDF DOCUMENTS VIEW
TEP FACILITIES MAP.PDF DOCUMENTS VIEW
UNAPPROVED DEVELOPMENT LETTER.PDF DOCUMENTS VIEW
1_BROWN-RITA LOTS 8-12_ DRAINAGE REPORT_V1.PDF PLANS UNDER REVIEW VIEW
1_BROWN-RITA LOT 12_ DP_PLAN_V1.PDF PLANS UNDER REVIEW VIEW
1_ LOT 12 NPPO EXCEPTION SET_V1.PDF PLANS UNDER REVIEW VIEW