Permit Details

Status:
Issued
Type:
Utilities Permit
Address:
1720 E ROGER RD
Address NEW:
1720 E ROGER RD
Apply Date:
12/09/2022
Applicant:
Description:
CHANGES ON THE EXISTING AT&T ANTENNA ARRAY: · INSTALL (2) NEW AT&T ANTENNA WITH INTEGRATED RRH UNIT PER SECTOR, (3) SECTORS, (6) TOTAL ON POSITION 1 · INSTALL (1) NEW DC9 SURGE · INSTALL (1) NEW 24 PAIR FIBER CABLE · INSTALL (3) NEW 6AWG DC CABLES · INSTALL (1) WCS FILTER FOR BETA SECTOR ON POSITION 3 · REMOVE (6) EXISTING TMAs PER SECTOR, (3) SECTORS, (18) TOTAL · REMOVE (3) EXISTING ANTENNAS PER SECTOR, (3) SECTORS, (9) TOTAL · INSTALL (2) NEW ROSENBERGER #2 GROUND WIRE PER MFG. SPEC'S FOR ALL NEW INSTALLATIONS · REMOVE (6) LINES OF COAX CABLES CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: (NO NEW SHELTER PROPOSED) · INSTALL (6) NEW RRHs · INSTALL (1) NEW FLEX21 CABINET · INSTALL (6) NEW TRIPLEXERS · REMOVE (12) EXISTING RRHs · REMOVE (1) EXISTING LTE CABINET · REMOVE (6) EXISTING QUADPLEXERS AC/DC SCOPE: DC POWER PLAN REVIEW: · EXISTING VERTIV NETSURE 512 -48VDC POWER PLANT [NEQ.19918] OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (3) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ. 15929]. INSTALL (1) ADDITIONAL HE 2KW -48VDC RECTIFIER [NEQ. 15930] TO MEET N+1 REQUIREMENT. · NEW DC BREAKERS IN EXISITNG POWER PLANT AS FOLLOWS ·· (2) 100A [NEQ. 00187] FLX21-2520 ·· (3) 50A [NEQ.00710] AIRSCALE DUAL BAND B25/66 AHFIB ·· (3) 50A [NEQ.00710] AIRSCALE DUAL BAND B12/14 AHLBA ·· (6) 40A [NEQ.00185] AEQ SERIES BATTERY CHECK: · BATTERY RESERVE CAPACITY: REMOVE (32) EXISTING MARATHON M12V155FT BATTERIES. INSTALL (12) NEW GNB M12V180FTX BATTERIES [NEQ.19872] IN BOTTOM SECTION OF NEW DC POWER SYSTEM. INSTALL (20) NEW GNB M12V180FTX BATTERIES [NEQ.16622] IN VERTIV NETXEND FLEX BATTERY CABINET. CONFIGURE BATTERIES FOR -48V OPERATION AS (4) CELLS PER STRING. FIVE BATTERY STRINGS WILL PROVIDE 4.2 HOURS OF BATTERY BACKUP. · NO PERMANENT STANDBY GENERATOR, MINIMUM REQUIRED BATTERY BACKUP TIME IS 4.0 HOURS. A/C PANEL REVIEW: · SEE PANEL SCHEDULE HVAC UNITS: · SITE HAS TWO EXISTING 4-TON HVAC UNITS, WHICH ARE SUFFICIENT

Permit Reviews

Permit Number - TC-UTL-1222-00027
Permit Status: Issued
Permit Description: CHANGES ON THE EXISTING AT&T ANTENNA ARRAY: · INSTALL (2) NEW AT&T ANTENNA WITH INTEGRATED RRH UNIT PER SECTOR, (3) SECTORS, (6) TOTAL ON POSITION 1 · INSTALL (1) NEW DC9 SURGE · INSTALL (1) NEW 24 PAIR FIBER CABLE · INSTALL (3) NEW 6AWG DC CABLES · INSTALL (1) WCS FILTER FOR BETA SECTOR ON POSITION 3 · REMOVE (6) EXISTING TMAs PER SECTOR, (3) SECTORS, (18) TOTAL · REMOVE (3) EXISTING ANTENNAS PER SECTOR, (3) SECTORS, (9) TOTAL · INSTALL (2) NEW ROSENBERGER #2 GROUND WIRE PER MFG. SPEC'S FOR ALL NEW INSTALLATIONS · REMOVE (6) LINES OF COAX CABLES CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: (NO NEW SHELTER PROPOSED) · INSTALL (6) NEW RRHs · INSTALL (1) NEW FLEX21 CABINET · INSTALL (6) NEW TRIPLEXERS · REMOVE (12) EXISTING RRHs · REMOVE (1) EXISTING LTE CABINET · REMOVE (6) EXISTING QUADPLEXERS AC/DC SCOPE: DC POWER PLAN REVIEW: · EXISTING VERTIV NETSURE 512 -48VDC POWER PLANT [NEQ.19918] OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (3) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ. 15929]. INSTALL (1) ADDITIONAL HE 2KW -48VDC RECTIFIER [NEQ. 15930] TO MEET N+1 REQUIREMENT. · NEW DC BREAKERS IN EXISITNG POWER PLANT AS FOLLOWS ·· (2) 100A [NEQ. 00187] FLX21-2520 ·· (3) 50A [NEQ.00710] AIRSCALE DUAL BAND B25/66 AHFIB ·· (3) 50A [NEQ.00710] AIRSCALE DUAL BAND B12/14 AHLBA ·· (6) 40A [NEQ.00185] AEQ SERIES BATTERY CHECK: · BATTERY RESERVE CAPACITY: REMOVE (32) EXISTING MARATHON M12V155FT BATTERIES. INSTALL (12) NEW GNB M12V180FTX BATTERIES [NEQ.19872] IN BOTTOM SECTION OF NEW DC POWER SYSTEM. INSTALL (20) NEW GNB M12V180FTX BATTERIES [NEQ.16622] IN VERTIV NETXEND FLEX BATTERY CABINET. CONFIGURE BATTERIES FOR -48V OPERATION AS (4) CELLS PER STRING. FIVE BATTERY STRINGS WILL PROVIDE 4.2 HOURS OF BATTERY BACKUP. · NO PERMANENT STANDBY GENERATOR, MINIMUM REQUIRED BATTERY BACKUP TIME IS 4.0 HOURS. A/C PANEL REVIEW: · SEE PANEL SCHEDULE HVAC UNITS: · SITE HAS TWO EXISTING 4-TON HVAC UNITS, WHICH ARE SUFFICIENT
Start Date Submittal Complete Date Status  
12/16/2022 UTILITIES REVIEW v.1 01/30/2023 APPROVED Review Details

Conditions

Permit Number - TC-UTL-1222-00027
Permit Status: Issued
Permit Description: CHANGES ON THE EXISTING AT&T ANTENNA ARRAY: · INSTALL (2) NEW AT&T ANTENNA WITH INTEGRATED RRH UNIT PER SECTOR, (3) SECTORS, (6) TOTAL ON POSITION 1 · INSTALL (1) NEW DC9 SURGE · INSTALL (1) NEW 24 PAIR FIBER CABLE · INSTALL (3) NEW 6AWG DC CABLES · INSTALL (1) WCS FILTER FOR BETA SECTOR ON POSITION 3 · REMOVE (6) EXISTING TMAs PER SECTOR, (3) SECTORS, (18) TOTAL · REMOVE (3) EXISTING ANTENNAS PER SECTOR, (3) SECTORS, (9) TOTAL · INSTALL (2) NEW ROSENBERGER #2 GROUND WIRE PER MFG. SPEC'S FOR ALL NEW INSTALLATIONS · REMOVE (6) LINES OF COAX CABLES CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: (NO NEW SHELTER PROPOSED) · INSTALL (6) NEW RRHs · INSTALL (1) NEW FLEX21 CABINET · INSTALL (6) NEW TRIPLEXERS · REMOVE (12) EXISTING RRHs · REMOVE (1) EXISTING LTE CABINET · REMOVE (6) EXISTING QUADPLEXERS AC/DC SCOPE: DC POWER PLAN REVIEW: · EXISTING VERTIV NETSURE 512 -48VDC POWER PLANT [NEQ.19918] OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (3) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ. 15929]. INSTALL (1) ADDITIONAL HE 2KW -48VDC RECTIFIER [NEQ. 15930] TO MEET N+1 REQUIREMENT. · NEW DC BREAKERS IN EXISITNG POWER PLANT AS FOLLOWS ·· (2) 100A [NEQ. 00187] FLX21-2520 ·· (3) 50A [NEQ.00710] AIRSCALE DUAL BAND B25/66 AHFIB ·· (3) 50A [NEQ.00710] AIRSCALE DUAL BAND B12/14 AHLBA ·· (6) 40A [NEQ.00185] AEQ SERIES BATTERY CHECK: · BATTERY RESERVE CAPACITY: REMOVE (32) EXISTING MARATHON M12V155FT BATTERIES. INSTALL (12) NEW GNB M12V180FTX BATTERIES [NEQ.19872] IN BOTTOM SECTION OF NEW DC POWER SYSTEM. INSTALL (20) NEW GNB M12V180FTX BATTERIES [NEQ.16622] IN VERTIV NETXEND FLEX BATTERY CABINET. CONFIGURE BATTERIES FOR -48V OPERATION AS (4) CELLS PER STRING. FIVE BATTERY STRINGS WILL PROVIDE 4.2 HOURS OF BATTERY BACKUP. · NO PERMANENT STANDBY GENERATOR, MINIMUM REQUIRED BATTERY BACKUP TIME IS 4.0 HOURS. A/C PANEL REVIEW: · SEE PANEL SCHEDULE HVAC UNITS: · SITE HAS TWO EXISTING 4-TON HVAC UNITS, WHICH ARE SUFFICIENT
Date Description Comments
02/08/2023 Contractor's active Arizona Contractor's License number for specified scope of work required prior to issuance of permit.