Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Address Search: 1720 E ROGER RD
Search
Parcel Attributes
| Parcel | 11301003D |
|---|---|
| Jurisdiction | Tucson, Pima County |
| Water Course | Wash |
| City of Tucson Zoning | R-1, MH-1 |
| Tucson Ward | Ward 3 |
| Tucson Registered Neighborhood | Campus Farm |
| Major Street & Route | Gateway Route, Arterial or Collector |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Parcel Attributes Issue? | |
Annexations & Original City Zoning (OCZ)
Address: 1720 E ROGER RD
Date - 12/06/2025 11:05 p.m.
Total Number Of Annexations & Original City Zoning (1)
Rezoning Cases
Date - 12/06/2025 11:05 p.m.
Total Number Of Rezone Cases - (4)
Permits
Address: 1720 E ROGER RD
Date - 12/06/2025 11:05 p.m.
Total Number Of Permits - (3)
| Permit | Status | Apply Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TC-UTL-1222-00027 | Issued | 12/09/2022 | 10/03/2023 | Utilities Permit | CHANGES ON THE EXISTING AT&T ANTENNA ARRAY: · INSTALL (2) NEW AT&T ANTENNA WITH INTEGRATED RRH UNIT PER SECTOR, (3) SECTORS, (6) TOTAL ON POSITION 1 · INSTALL (1) NEW DC9 SURGE · INSTALL (1) NEW 24 PAIR FIBER CABLE · INSTALL (3) NEW 6AWG DC CABLES · INSTALL (1) WCS FILTER FOR BETA SECTOR ON POSITION 3 · REMOVE (6) EXISTING TMAs PER SECTOR, (3) SECTORS, (18) TOTAL · REMOVE (3) EXISTING ANTENNAS PER SECTOR, (3) SECTORS, (9) TOTAL · INSTALL (2) NEW ROSENBERGER #2 GROUND WIRE PER MFG. SPEC'S FOR ALL NEW INSTALLATIONS · REMOVE (6) LINES OF COAX CABLES CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: (NO NEW SHELTER PROPOSED) · INSTALL (6) NEW RRHs · INSTALL (1) NEW FLEX21 CABINET · INSTALL (6) NEW TRIPLEXERS · REMOVE (12) EXISTING RRHs · REMOVE (1) EXISTING LTE CABINET · REMOVE (6) EXISTING QUADPLEXERS AC/DC SCOPE: DC POWER PLAN REVIEW: · EXISTING VERTIV NETSURE 512 -48VDC POWER PLANT [NEQ.19918] OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (3) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ. 15929]. INSTALL (1) ADDITIONAL HE 2KW -48VDC RECTIFIER [NEQ. 15930] TO MEET N+1 REQUIREMENT. · NEW DC BREAKERS IN EXISITNG POWER PLANT AS FOLLOWS ·· (2) 100A [NEQ. 00187] FLX21-2520 ·· (3) 50A [NEQ.00710] AIRSCALE DUAL BAND B25/66 AHFIB ·· (3) 50A [NEQ.00710] AIRSCALE DUAL BAND B12/14 AHLBA ·· (6) 40A [NEQ.00185] AEQ SERIES BATTERY CHECK: · BATTERY RESERVE CAPACITY: REMOVE (32) EXISTING MARATHON M12V155FT BATTERIES. INSTALL (12) NEW GNB M12V180FTX BATTERIES [NEQ.19872] IN BOTTOM SECTION OF NEW DC POWER SYSTEM. INSTALL (20) NEW GNB M12V180FTX BATTERIES [NEQ.16622] IN VERTIV NETXEND FLEX BATTERY CABINET. CONFIGURE BATTERIES FOR -48V OPERATION AS (4) CELLS PER STRING. FIVE BATTERY STRINGS WILL PROVIDE 4.2 HOURS OF BATTERY BACKUP. · NO PERMANENT STANDBY GENERATOR, MINIMUM REQUIRED BATTERY BACKUP TIME IS 4.0 HOURS. A/C PANEL REVIEW: · SEE PANEL SCHEDULE HVAC UNITS: · SITE HAS TWO EXISTING 4-TON HVAC UNITS, WHICH ARE SUFFICIENT | |
| T15TC02621 | EXPIRED | 11/18/2015 | N/A | BARRICAD | CELL TOWER WORK | |
| T18CM09572 | FINAL | 12/07/2018 | 04/01/2020 | COMBO | CELL TOWER |