Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
3762 E 22ND ST UNIT 1
Apply Date:
12/22/2025
Applicant:
Jose Cardenas
Description:
CAR COLLISION REBUILD DUPLEX COT-ENFC-Code

Permit Reviews

Permit Number - TC-RES-1225-06108
Permit Status: Complete
Permit Description: CAR COLLISION REBUILD DUPLEX COT-ENFC-Code
Start Date Submittal Complete Date Status  
12/24/2025 RESIDENTIAL ADD/ALT v.1 01/16/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-1225-06108
Permit Status: Complete
Permit Description: CAR COLLISION REBUILD DUPLEX COT-ENFC-Code
Date Description Comments
05/12/2026 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-1225-06108
Permite Description: CAR COLLISION REBUILD DUPLEX COT-ENFC-Code
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
03/16/2026 COT - RSBU - Excavation/Rebar/Zoning N/A Partial Pass 3/16/2026
Partial pass. Okay to proceed with second lift at CMU wall.
04/16/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 4/16/26: Discrepancies at post to beam connections most restrictive will
Be required.(Simpson Post cap PC6Z missing at post to beam connection, and strong-tie CCQ66SDS2.5) , 2x6 rafters shall be bearing minimum 1 1/2” on beam (R802.6), Simpson post base shall be properly fastened and required to have 1” clearance from grade all around. Ladder required for roof nailing inspection. Please recall inspection once items have been addressed.
03/09/2026 RSPL - Plumbing Progress N/A Partial Pass UG Plumbing

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-1225-06108
Permit Description: CAR COLLISION REBUILD DUPLEX COT-ENFC-Code
Total Completed Inspections - 9
Date Description Inspector Results Comments
03/16/2026 RSEL - Electrical Progress Passed 3/16/2026
Verified replaced like-for-like electrical in bathroom. Call in remaining mechanical, electrical, plumbing rough-in at intermediate inspection. Ensure water and DWV lines under test.
03/17/2026 COT - RSBU - Excavation/Rebar/Zoning Passed masonry top-out
04/20/2026 COT - RSBU - Roof Nailing Passed
04/20/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed All corrections were completed. 4/20/2026
04/23/2026 RSPL - Plumbing Progress Passed 4/23/26 passed
04/23/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 4/23/26 passed
05/11/2026 RSBU - Building Final Passed Passed 5/11/26
05/11/2026 COT - RSEL - Electrical Final Passed Passed 5/11/26
05/11/2026 COT - RSPL - Plumbing Final Passed Passed 5/11/26

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-KR PDF_V1.PDF DOCUMENTS VIEW