Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 4/16/26: Discrepancies at post to beam connections most restrictive will Be required.(Simpson Post cap PC6Z missing at post to beam connection, and strong-tie CCQ66SDS2.5) , 2x6 rafters shall be bearing minimum 1 1/2” on beam (R802.6), Simpson post base shall be properly fastened and required to have 1” clearance from grade all around. Ladder required for roof nailing inspection. Please recall inspection once items have been addressed. |
|
| 04/20/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | All corrections were completed. 4/20/2026 |