Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
04/16/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 4/16/26: Discrepancies at post to beam connections most restrictive will
Be required.(Simpson Post cap PC6Z missing at post to beam connection, and strong-tie CCQ66SDS2.5) , 2x6 rafters shall be bearing minimum 1 1/2” on beam (R802.6), Simpson post base shall be properly fastened and required to have 1” clearance from grade all around. Ladder required for roof nailing inspection. Please recall inspection once items have been addressed.
04/20/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed All corrections were completed. 4/20/2026