Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
2251 E FLORENCE DR
Apply Date:
12/04/2025
Applicant:
Delta Mechanical
Description:
replace 40g/40k btu gas water heater like for like

Permit Reviews

Permit Number - TC-RES-1225-05811
Permit Status: Complete
Permit Description: replace 40g/40k btu gas water heater like for like
Start Date Submittal Complete Date Status  
12/05/2025 RESIDENTIAL SIMPLE REVIEW v.1 12/19/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-1225-05811
Permit Status: Complete
Permit Description: replace 40g/40k btu gas water heater like for like
Date Description Comments
12/05/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-1225-05811
Permite Description: replace 40g/40k btu gas water heater like for like
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
01/22/2026 COT - RSME - Mechanical Final N/A Not Ready
01/22/2026 RSBU - Building Final N/A Not Ready please install three screws at each joint for the flu pipe, including the top of the water heater and the double wall at the ceiling and remove metal metallic tape. Supply gas line has several elbows in the drop place to wall mounts at one at the top and one at the bottom so that the pipe is not easily twisted.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-1225-05811
Permit Description: replace 40g/40k btu gas water heater like for like
Total Completed Inspections - 2
Date Description Inspector Results Comments
02/19/2026 COT - RSME - Mechanical Final Passed
02/19/2026 RSBU - Building Final Passed All corrections were made. 2/19/2026

Documents

File Name Document Type  
2251 E FLORENCE DR - SITE MAPS_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW