Permit: TC-RES-1225-05764
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
540 S EVENING ROSE AV
Address NEW:
540 S EVENING ROSE AV
Apply Date:
12/02/2025
Applicant:
Heather Tilson
Description:
REV1: Added sf to shed, patio/shade structure and total lot coverage; no electricity to either structure game room addition
Permit Reviews
Permit Number - TC-RES-1225-05764
Permit Status: Inspections
Permit Description: REV1: Added sf to shed, patio/shade structure and total lot coverage; no electricity to either structure
game room addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/22/2026 | ADMINISTRATIVE v.3 | 01/22/2026 | APPROVED |
| 12/08/2025 | RESIDENTIAL ADD/ALT v.1 | 01/05/2026 | APPROVED |
| 02/27/2026 | RESIDENTIAL NEW DWELLING REVISION v.1 | 03/18/2026 | REQUIRES RESUBMIT |
| 03/27/2026 | RESIDENTIAL NEW DWELLING REVISION v.3 | 04/10/2026 | APPROVED |
| 01/09/2026 | ADMINISTRATIVE v.2 | 01/09/2026 | REQUIRES RESUBMIT |
| 01/05/2026 | ADMINISTRATIVE v.1 | 01/05/2026 | REQUIRES RESUBMIT |
| 03/20/2026 | RESIDENTIAL NEW DWELLING REVISION v.2 | N/A | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-1225-05764
Permit Status: Inspections
Permit Description: REV1: Added sf to shed, patio/shade structure and total lot coverage; no electricity to either structure
game room addition
| Date | Description | Comments |
|---|---|---|
| 12/08/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-1225-05764
Permite Description: REV1: Added sf to shed, patio/shade structure and total lot coverage; no electricity to either structure
game room addition
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/08/2026 | BULD - Electrical Clearance | N/A | Not Applicable | N/A customer is using a sub-panel. No extra meter needed. |
| 07/08/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 1. Seal all top plate penetrations with fire caulk or fire putty. 2. Add blocking for future grab bars in bathroom 3. Cannot have insulation up before intermediates are passed. Remove insulation for re-inspection. 4. Secure all plumbing lines and have under test. 5. Wrap hose bib copper in 10 mil tape before stucco. 6. Weep creed needs to be Minimum of 4" from dirt or 2" from concrete. 7. Main water line not connected. 8. HVAC line set have not been set yet, condenser pad installed yet. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-1225-05764
Permit Description: REV1: Added sf to shed, patio/shade structure and total lot coverage; no electricity to either structure
game room addition
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Passed | |
| 06/04/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 6/4/26 1. Add anchor bolts every 32" 2. Add blocking in bathroom for future grab bars. This can be checked at intermediate, ok to move onto intermediates. |
|
| 07/08/2026 | RSEL - Electrical Progress | Passed | ||
| 07/10/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed |