Permit: TC-RES-1224-07264
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
6648 E DAVID DR
Address NEW:
6648 E DAVID DR
Apply Date:
12/13/2024
Applicant:
Hailey McGraw
Description:
install 3.69kw residential roof mounted solar, 1 Enphase IQ 5P (non-backup), and new sub panel. REV1: Relocated all home loads into a New 200A raged sub panel with 200A MB fed from lug kit in MSP.
Permit Reviews
Permit Number - TC-RES-1224-07264
Permit Status: Complete
Permit Description: install 3.69kw residential roof mounted solar, 1 Enphase IQ 5P (non-backup), and new sub panel.
REV1: Relocated all home loads into a New 200A raged sub panel with 200A MB fed from lug kit in MSP.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/13/2024 | RESIDENTIAL SOLAR v.1 | 01/14/2025 | APPROVED |
| 04/07/2025 | RESIDENTIAL SOLAR REVISION v.1 | 05/02/2025 | APPROVED |
| 01/24/2025 | RESIDENTIAL SOLAR REVISION v.1 | 02/24/2025 | APPROVED |
Conditions
Permit Number - TC-RES-1224-07264
Permit Status: Complete
Permit Description: install 3.69kw residential roof mounted solar, 1 Enphase IQ 5P (non-backup), and new sub panel.
REV1: Relocated all home loads into a New 200A raged sub panel with 200A MB fed from lug kit in MSP.
| Date | Description | Comments |
|---|---|---|
| 01/02/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-1224-07264
Permit Description: install 3.69kw residential roof mounted solar, 1 Enphase IQ 5P (non-backup), and new sub panel.
REV1: Relocated all home loads into a New 200A raged sub panel with 200A MB fed from lug kit in MSP.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/25/2025 | BULD - Electrical Clearance | Passed | 6.25.25 Solar system is installed per plans. Proper conductors, bracing, hardware and grounding used throughout. Labels present every ten ft on conduit. Lower portion of system is AC not DC, Inverters are on roof so no DC conduit labels required below roof line and therefore are not present. |
|
| 06/25/2025 | COT - RSOL - Electrical Final Solar Project | Passed | 6.25.25 Solar system is installed per plans. Proper conductors, bracing, hardware and grounding used throughout. Labels present every ten ft on conduit. Lower portion of system is AC not DC, Inverters are on roof so no DC conduit labels required below roof line and therefore are not present. |