Permit: TC-RES-1222-01320
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
5143 E ADAMS ST
Address NEW:
5143 E ADAMS ST
Apply Date:
12/06/2022
Applicant:
Mary Hayn
Description:
28' x 14' 392 SF NEW POOL
Permit Reviews
Permit Number - TC-RES-1222-01320
Permit Status: Complete
Permit Description: 28' x 14' 392 SF NEW POOL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/05/2023 | RESIDENTIAL NEW DWELLING v.2 | 03/07/2023 | REQUIRES RESUBMIT |
| 01/30/2023 | RESIDENTIAL NEW DWELLING v.1 | 03/01/2023 | REQUIRES RESUBMIT |
| 03/13/2023 | RESIDENTIAL NEW DWELLING v.3 | 04/07/2023 | APPROVED |
Conditions
Permit Number - TC-RES-1222-01320
Permit Status: Complete
Permit Description: 28' x 14' 392 SF NEW POOL
| Date | Description | Comments |
|---|---|---|
| 04/07/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-1222-01320
Permite Description: 28' x 14' 392 SF NEW POOL
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2023 | RSEL - Electrical Progress | N/A | Partial Pass | Conduit for pool light is installed in trench running to pool pump location. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-1222-01320
Permit Description: 28' x 14' 392 SF NEW POOL
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2023 | Pool/Spa - Bonding Grip | Passed | Bonding wire is installed all the way around pool and connected to the rebar as a ufer ground and ran to the pool pump location. | |
| 05/24/2023 | Pool/Spa - Plumbing | Passed | underground plumbing is complete for pool and pool pump. okay to backfill trench. | |
| 05/24/2023 | Pool/Spa - Pre-Gunite | Passed | All rebar reinforcement is installed, edge forms are in place, rebar dobies are in place holding reinforcement off the ground. Okay to apply gunite. | |
| 02/16/2024 | Pool/Spa - Gas | Passed | Gas line is installed in trench with yellow tracer wire, gas line is under an air pressure test and holding 20# of air. Okay to connect to gas meter and backfill trench. | |
| 02/16/2024 | COT - BULD - SWG Clearance | Passed | Gas line is installed in trench with yellow tracer wire, gas line is under an air pressure test and holding 20# of air. Okay to connect to gas meter and backfill trench. | |
| 01/31/2025 | Pool/Spa - Electric | Passed | ||
| 01/23/2025 | Pool/Spa - Final/Barrier | Passed | ||
| 01/23/2025 | RSBU - Building Final | Passed | ||
| 01/23/2025 | RSEL - Electrical Progress | Passed | ||
| 01/23/2025 | COT - RSEL - Electrical Final | Passed |