Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Apply Date:
11/19/2025
Applicant:
Ana Rojas
Description:
Duplex

Permit Reviews

Permit Number - TC-RES-1125-05611
Permit Status: Inspections complete
Permit Description: Duplex
Start Date Submittal Complete Date Status  
11/25/2025 RESIDENTIAL NEW DWELLING v.1 12/05/2025 REQUIRES RESUBMIT Review Details
04/15/2026 RESIDENTIAL NEW DWELLING v.2 05/01/2026 APPROVED Review Details
05/06/2026 ADMINISTRATIVE v.2 N/A REQUIRES RESUBMIT Review Details
05/01/2026 ADMINISTRATIVE v.1 N/A REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-1125-05611
Permit Status: Inspections complete
Permit Description: Duplex
Total Outstanding Activity Conditions - 3
Date Name
11/26/2025 Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
11/26/2025 Manual J report
11/26/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-1125-05611
Permit Status: Inspections complete
Permit Description: Duplex
Date Description Comments
11/25/2025 The permit and plan show to be for a Duplex and requires two separate addresses, one for each unit of the duplex. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to assign/add the units or a new address for this Duplex. A change of address request will need to be submitted in order to properly update the location of this permit once the addressing is complete. Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf For questions: PDSD-Residential@tucsonaz.gov
11/25/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
11/25/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-1125-05611
Permite Description: Duplex
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
05/26/2026 COT - RSBU - Preslab N/A Re-inspection required 5-26-26: clear out footings of loose debris, compact pad near interior footing, add reinforcement at hold-downs and extend reinforcement 2' at all corners, per IRC 506.3.3, a vapor retarder is required at all monolithic slabs & footings, 2 ground rods will be required rather than attaching copper to reinforcement, 1 1/2" clearance from DWV and forms. Note: an exception to the vapor barrier requires a stamped letter from an engineer. The letter would have to be submitted to the city for review and approval.
06/17/2026 COT - RSBU - Firewall/Fire Barrier/Firestop N/A Partial Pass 06/17/2026
Verified 5/8" type-x gypsum at interior common firewall. Partial pass pending exterior panels, call in prior to tape and texture.
10/05/2026 RSBU - Building Final N/A Re-inspection required 10/5/26: reverse polarity at southwest receptacle of bedroom 3, add insulation to hot leg of water heaters, and relocate pex lines at entrance to attic.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-1125-05611
Permit Description: Duplex
Total Completed Inspections - 17
Date Description Inspector Results Comments
05/19/2026 COT - RSPL - Rough Soil Passed Okay to backfill. Shading required. 5/19/2026
05/29/2026 COT - RSBU - Excavation/Rebar/Zoning Passed
05/29/2026 COT - RSBU - Preslab Passed 5/29/2026 all corrections were made. Okay for concrete placement.
06/18/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 06/18/2026
Verified added short pins at marked locations and tightened anchor bolts throughout.
07/08/2026 COT - RSPL - Yard Water Line Passed Okay to backfill. Shading required. 7/8/2026
07/10/2026 BULD - Electrical Clearance Passed Clearance for TEP ECO. UNITS 1 AND 2. 7/10/2026
07/10/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed All corrections have been made. 7/10/2026
07/21/2026 COT - RSBU - Interior Shear Bracing Passed
07/21/2026 COT - RSBU - Firewall/Fire Barrier/Firestop Passed 07/21/2026
Verified nail schedule at firewall.
07/27/2026 COT - RSBU - Roof Nailing Passed 07/27/2026
Passed prior on 6/18/26.
09/08/2026 COT - RSPL - Sewer Passed 9/8/26: sewer verified under test & approved. Okay to backfill using shading materials.
10/05/2026 COT - RSEL - Electrical Underground Passed 10/5/26: approved.
10/05/2026 COT - RSEL - Outdoor Lighting Passed 10/5/26: approved.
10/05/2026 COT - RSME - Mechanical Final Passed 10/5/26: mechanical final approved.
10/05/2026 COT - RSPL - Plumbing Final Passed 10/5/26: plumbing final approved.
10/06/2026 RSBU - Building Final Passed 10/6/26: building final approved.
10/06/2026 COT - RSEL - Electrical Final Passed 10/6/26: electrical final approved.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
REVISED_PDSD_OWNER_BUILDER_AFFIDAVIT_V1 (8)_V2.PDF DOCUMENTS VIEW
RESPONSE LETTER_ TC-RES-1125-05611 - RESIDENTIAL BUILDING - NEW DUPLEX 1656 S SAN ANTONIO DR_V1.PDF DOCUMENTS VIEW
CONS-COMBINED MAURIIO SAN ANTONIO_V2.PDF DOCUMENTS VIEW
RESPONSE LETTER_ NEW DUPLEX 1656 S SAN ANTONIO DR_V1.PDF DOCUMENTS VIEW