Permit: TC-RES-1125-05359
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
2547 W CALLE PARAISO
Address NEW:
2547 W CALLE PARAISO
Apply Date:
11/04/2025
Applicant:
brian dunn
Description:
Repipe hot and cold service through the home.
Permit Reviews
Permit Number - TC-RES-1125-05359
Permit Status: Inspections
Permit Description: Repipe hot and cold service through the home.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/04/2025 | RESIDENTIAL SIMPLE REVIEW v.1 | 11/05/2025 | APPROVED |
Conditions
Permit Number - TC-RES-1125-05359
Permit Status: Inspections
Permit Description: Repipe hot and cold service through the home.
| Date | Description | Comments |
|---|---|---|
| 11/04/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-1125-05359
Permite Description: Repipe hot and cold service through the home.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/13/2025 | RSBU - Building Final | N/A | Not Ready | Not ready. Provide 18" of copper before transition to pex at main water line, water heater and rear hose bib. Secure loose angle stops. Insulate hot water lines that are running parallel with cold line. Seal all top penetrations with fire foam. Provide hammer arrestors at laundry room, hot line for dishwasher and refrigerator. Provide an ice maker outlet box for refrigerator. 11/13/2024 |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-1125-05359
Permit Description: Repipe hot and cold service through the home.
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/26/2025 | RSBU - Building Final | Passed | 11.26.25 Approved |