Inspection History Details
Inspection Status: Not Ready
Inspection History: RSBU - Building Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/13/2025 | RSBU - Building Final | Not Ready | Not ready. Provide 18" of copper before transition to pex at main water line, water heater and rear hose bib. Secure loose angle stops. Insulate hot water lines that are running parallel with cold line. Seal all top penetrations with fire foam. Provide hammer arrestors at laundry room, hot line for dishwasher and refrigerator. Provide an ice maker outlet box for refrigerator. 11/13/2024 | |
| 11/21/2025 | RSBU - Building Final | Re-inspection required | 11-21-25: missing hammer arrestor at refrigerator. The copper line in wall behind for the water heater requires a total of 18" of copper before it transitions to pex. Also, R3 insulation is required for the hot water leg of the water heater. Reschedule inspection when ready. | |
| 11/26/2025 | RSBU - Building Final | Passed | 11.26.25 Approved |