03/04/2024 RESIDENTIAL NEW DWELLING v.2 03/26/2024 APPROVED Review Details
10/02/2024 RESIDENTIAL NEW DWELLING v.1 10/03/2024 APPROVED Review Details
12/05/2023 RESIDENTIAL NEW DWELLING v.1 01/02/2024 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-1123-09821
Permit Status: Issued
Permit Description: SFR & Sleeping Quarters
Total Outstanding Activity Conditions - 2
Date Name
05/02/2024 Submission of the final Elevation Certificate and completion of the Floodplain Use Permit is required PRIOR TO FINALING this permit.
12/14/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-1123-09821
Permit Status: Issued
Permit Description: SFR & Sleeping Quarters
Date Description Comments
03/26/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
05/02/2024 An intermediate Elevation Certificate is required PRIOR TO GRADING and/or PRE-SLAB INSPECTION.
12/14/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-RES-1123-09821
Permite Description: SFR & Sleeping Quarters
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
10/22/2024 COT - RSME - Mechanical Final N/A Not Ready
10/22/2024 COT - RSPL - Plumbing Final N/A Not Ready
10/22/2024 BULD - Electrical Clearance N/A Re-inspection required 10/22/24: properly seal all penetrations through vapor barrier and top plate, secure gas piping on vertical and horizontal runs, all metallic boxes must be grounded, address tag missing at panel, plans call for 400amp service, sub panel requires ground busbar, gas piping must be grounded, transition glue at abs and pvc not allowed, outlet missing at guest house at kitchen wall, properly secure condensate drain. B-vent must be properly secured with 1 inch clearance from combustibles, BOCA plates required throughout at dryer vent and plumbing. Stopped inspection more items may be added

Completed Inspections

Permit Status: Issued
Permit Number: TC-RES-1123-09821
Permit Description: SFR & Sleeping Quarters
Total Completed Inspections - 8
Date Description Inspector Results Comments
08/07/2024 COT - RSPL - Rough Soil Passed 8/7/24: plumbing underground per plans ok to proceed with backfill. Shading required
08/19/2024 COT - RSBU - Preslab and floodplain Passed
08/19/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
09/16/2024 COT - RSBU - Roof Nailing Passed
09/18/2024 COT - RSBU - Exterior Clips/Sheathing Passed Approved. All corrections were made. 9/18/2024
10/29/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed All corrections were made. Approved. 10/29/2024
10/29/2024 COT - RSBU - Interior Shear Bracing Passed
10/29/2024 BULD - Electrical Clearance Passed Clearance for TEP ECO. 10/29/2024

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-3_PLAN_SET_V2 PAGE 6_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
PDSD_OWNER_BUILDER_AFFIDAVIT_081623_V1_V1.PDF DOCUMENTS VIEW
CONS-3_PLAN_SET_V2.PDF DOCUMENTS VIEW