Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-RES-1123-09821
Permit Details
Apply Date:
11/30/2023
Applicant:
Rogelio Duarte
Description:
SFR & Sleeping Quarters
Permit Reviews
Permit Number - TC-RES-1123-09821
Permit Status: Issued
Permit Description: SFR & Sleeping Quarters
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/04/2024 | RESIDENTIAL NEW DWELLING v.2 | 03/26/2024 | APPROVED |
10/02/2024 | RESIDENTIAL NEW DWELLING v.1 | 10/03/2024 | APPROVED |
12/05/2023 | RESIDENTIAL NEW DWELLING v.1 | 01/02/2024 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-RES-1123-09821
Permit Status: Issued
Permit Description: SFR & Sleeping Quarters
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
05/02/2024 | Submission of the final Elevation Certificate and completion of the Floodplain Use Permit is required PRIOR TO FINALING this permit. |
12/14/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-RES-1123-09821
Permit Status: Issued
Permit Description: SFR & Sleeping Quarters
Date | Description | Comments |
---|---|---|
03/26/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
05/02/2024 | An intermediate Elevation Certificate is required PRIOR TO GRADING and/or PRE-SLAB INSPECTION. | |
12/14/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-RES-1123-09821
Permite Description: SFR & Sleeping Quarters
Total Outstanding Inspections - 3
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/22/2024 | COT - RSME - Mechanical Final | N/A | Not Ready | |
10/22/2024 | COT - RSPL - Plumbing Final | N/A | Not Ready | |
10/22/2024 | BULD - Electrical Clearance | N/A | Re-inspection required | 10/22/24: properly seal all penetrations through vapor barrier and top plate, secure gas piping on vertical and horizontal runs, all metallic boxes must be grounded, address tag missing at panel, plans call for 400amp service, sub panel requires ground busbar, gas piping must be grounded, transition glue at abs and pvc not allowed, outlet missing at guest house at kitchen wall, properly secure condensate drain. B-vent must be properly secured with 1 inch clearance from combustibles, BOCA plates required throughout at dryer vent and plumbing. Stopped inspection more items may be added |
Completed Inspections
Permit Status: Issued
Permit Number: TC-RES-1123-09821
Permit Description: SFR & Sleeping Quarters
Total Completed Inspections - 8
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/07/2024 | COT - RSPL - Rough Soil | Passed | 8/7/24: plumbing underground per plans ok to proceed with backfill. Shading required | |
08/19/2024 | COT - RSBU - Preslab and floodplain | Passed | ||
08/19/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
09/16/2024 | COT - RSBU - Roof Nailing | Passed | ||
09/18/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Approved. All corrections were made. 9/18/2024 | |
10/29/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | All corrections were made. Approved. 10/29/2024 | |
10/29/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
10/29/2024 | BULD - Electrical Clearance | Passed | Clearance for TEP ECO. 10/29/2024 |