Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
2315 W WAGON WHEELS DR
Apply Date:
11/06/2023
Applicant:
Inai Maldonado
Description:
Rebuild SFR

Permit Reviews

Permit Number - TC-RES-1123-09317
Permit Status: Complete
Permit Description: Rebuild SFR
Start Date Submittal Complete Date Status  
11/08/2023 RESIDENTIAL NEW DWELLING v.1 12/12/2023 REQUIRES RESUBMIT Review Details
12/18/2023 RESIDENTIAL NEW DWELLING v.3 12/18/2023 REQUIRES RESUBMIT Review Details
12/18/2023 RESIDENTIAL NEW DWELLING v.2 12/18/2023 REQUIRES RESUBMIT Review Details
02/01/2024 RESIDENTIAL NEW DWELLING v.1 02/06/2024 APPROVED Review Details
12/29/2023 RESTAMP - RESIDENTIAL v.1 12/29/2023 APPROVED Review Details
12/19/2023 RESIDENTIAL NEW DWELLING v.4 12/29/2023 APPROVED Review Details

Conditions

Permit Number - TC-RES-1123-09317
Permit Status: Complete
Permit Description: Rebuild SFR
Date Description Comments
03/18/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
03/18/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
03/18/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
03/18/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-1123-09317
Permit Description: Rebuild SFR
Total Completed Inspections - 14
Date Description Inspector Results Comments
01/04/2024 COT - RSPL - Rough Soil Passed
01/10/2024 COT - RSBU - Preslab Passed
01/11/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
02/16/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
02/16/2024 COT - RSBU - Roof Nailing Passed
03/15/2024 BULD - Electrical Clearance Passed Approved service panel upgrade, INCR Clearance to TEP is required for the reconnection
03/25/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
03/25/2024 COT - RSEL - Grounding/Bonding Passed
04/26/2024 COT - RSPL - Yard Water Line Passed Okay to back fill. Shading is required. 4/26/2024
05/29/2024 RSBU - Building Final Passed
05/29/2024 COT - RSEL - Electrical Final Passed
05/29/2024 COT - RSPL - Plumbing Final Passed
05/29/2024 COT - RSME - Mechanical Final Passed
05/29/2024 COT - RSEL - Outdoor Lighting Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
2315 REVISIONS_V1.PDF DOCUMENTS VIEW
2315 W WAGON WHEELS-PLAN SET VERSION 2_V2.PDF DOCUMENTS VIEW
R80426532.232814_V1.PDF DOCUMENTS VIEW
STUDWELL TRUSS LAYOUT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
OWNER AFFIDAVIT_V1.PDF DOCUMENTS VIEW
2315 W WAGON WHEELS-PLAN SET VERSION 2_V3.PDF DOCUMENTS VIEW
2315 W WAGON WHEELS-PLAN SET VERSION 2_V3.PDF DOCUMENTS VIEW