Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address NEW:
1209 E ADELAIDE DR
Apply Date:
10/18/2024
Applicant:
Dane Donatelli
Description:
REV_1, Change Door sizes; Replace SFR after demo TC-DMO-1024-00233

Permit Reviews

Permit Number - TC-RES-1024-06082
Permit Status: Inspections complete
Permit Description: REV_1, Change Door sizes; Replace SFR after demo TC-DMO-1024-00233
Start Date Submittal Complete Date Status  
11/04/2025 RESIDENTIAL NEW DWELLING REVISION v.1 11/14/2025 APPROVED Review Details
10/18/2024 RESIDENTIAL NEW DWELLING v.1 11/27/2024 REQUIRES RESUBMIT Review Details
02/28/2025 RESIDENTIAL NEW DWELLING v.2 03/17/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-1024-06082
Permit Status: Inspections complete
Permit Description: REV_1, Change Door sizes; Replace SFR after demo TC-DMO-1024-00233
Total Outstanding Activity Conditions - 1
Date Name
10/30/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-1024-06082
Permit Status: Inspections complete
Permit Description: REV_1, Change Door sizes; Replace SFR after demo TC-DMO-1024-00233
Date Description Comments
02/28/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
10/31/2025 An intermediate Elevation Certificate is required PRIOR TO GRADING and/or PRE-SLAB INSPECTION.
10/31/2025 Submission of the final Elevation Certificate and completion of the Floodplain Use Permit is required PRIOR TO FINALING this permit.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-1024-06082
Permite Description: REV_1, Change Door sizes; Replace SFR after demo TC-DMO-1024-00233
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
06/20/2025 COT - RSPL - Sewer N/A Partial Pass 6/20/25
Partial pass, pending HCS connection. Ok to backfill progress areas.
06/20/2025 COT - RSPL - Rough Soil N/A Partial Pass 6/20/25
Partial pass, pending main water line.
10/30/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Partial Pass
07/10/2025 COT - RSEL - Grounding/Bonding N/A Partial Pass underslab
03/05/2026 RSBU - Building Final N/A Re-inspection required Insulate hot water line at water heater. Along with those at the exterior of the home. Provide cover plate at receptacle right of door entry at garage. Provide self closing door along with spec sheet on garage door. Provide shut off valves at utility sink. Provide smoke detector outside of master bedroom. Provide vacuum breakers at all hose bibs. Provide elbow at condensation line. Coat all exterior plastic pipes. Cut clean outs down to to grade and provide proper cap. Provide proper grading prior to final. 3/5/2026
08/03/2026 COT - BULD - SWG Clearance N/A Not Applicable

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-1024-06082
Permit Description: REV_1, Change Door sizes; Replace SFR after demo TC-DMO-1024-00233
Total Completed Inspections - 18

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
OBA 1024-06082 VERSION2025_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-1209 E ADELAIDE REVISION_V2.PDF DOCUMENTS VIEW