Permit: TC-RES-0925-04549
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
322 N FORGEUS AV UNIT 2
Address NEW:
322 N FORGEUS AV UNIT 2
Apply Date:
09/15/2025
Applicant:
alex enoch
Description:
REV1: Changed mechanical from split system to mini split ductless multizone; removed new 400a elec ses and show only one new 200a elec ses drop new adu
Permit Reviews
Permit Number - TC-RES-0925-04549
Permit Status: Inspections
Permit Description: REV1: Changed mechanical from split system to mini split ductless multizone; removed new 400a elec ses and show only one new 200a elec ses drop
new adu
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/26/2026 | RESIDENTIAL ADU REVISION v.1 | 07/02/2026 | APPROVED |
| 12/15/2025 | RESIDENTIAL NEW DWELLING v.2 | 12/26/2025 | REQUIRES RESUBMIT |
| 01/20/2026 | ADMINISTRATIVE v.1 | 01/20/2026 | REQUIRES RESUBMIT |
| 09/16/2025 | RESIDENTIAL NEW DWELLING v.1 | 10/22/2025 | REQUIRES RESUBMIT |
| 01/13/2026 | RESIDENTIAL NEW DWELLING v.3 | 01/20/2026 | APPROVED |
| 01/23/2026 | ADMINISTRATIVE v.2 | 01/23/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-0925-04549
Permit Status: Inspections
Permit Description: REV1: Changed mechanical from split system to mini split ductless multizone; removed new 400a elec ses and show only one new 200a elec ses drop
new adu
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/08/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-RES-0925-04549
Permit Status: Inspections
Permit Description: REV1: Changed mechanical from split system to mini split ductless multizone; removed new 400a elec ses and show only one new 200a elec ses drop
new adu
| Date | Description | Comments |
|---|---|---|
| 09/16/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 01/22/2026 | Please submit a Manual J report. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0925-04549
Permite Description: REV1: Changed mechanical from split system to mini split ductless multizone; removed new 400a elec ses and show only one new 200a elec ses drop
new adu
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/01/2026 | COT - RSBU - Interior Shear Bracing | N/A | Not Ready | 06/01/2026 Not ready. Call in when ready to verify drywall nail schedule prior to tape & texture. |
| 10/07/2026 | RSBU - Building Final | N/A | Re-inspection required | 7/10/26: Gfci receptacle required behind refrigerator, missing dishwasher hammer arrestor, mini split shall be UL listed-either replace or contact Intertek for an inspection and submit the report to the city for review & approval, exterior receptacles shall be weather resistant and covers must be rated heavy duty while in use, smoke detectors require a 4" clearance from walls, arch fault breakers required for every habitable areas, paint PVC/plastics, add a 90 degree elbow to pressure relief valve & a 6"clearance from grade, missing address on home, provide ladder for roof access, add R3 insulation to water heater heater copper lines, add a receptacle in bedroom behind door- required per code on a 2' foot wall, 1/2" max threshold required at front door. Stopped inspection-additional items may be noted and please schedule all remaining inspections when ready. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0925-04549
Permit Description: REV1: Changed mechanical from split system to mini split ductless multizone; removed new 400a elec ses and show only one new 200a elec ses drop
new adu
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2026 | COT - RSPL - Rough Soil | Passed | ||
| 04/30/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 04/30/2026 | COT - RSBU - Preslab | Passed | ||
| 05/28/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 06/01/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 06/01/2026 Corrections made to prior inspection. |
|
| 07/22/2026 | COT - RSBU - Interior Shear Bracing | Passed | 07/22/2026 Approved per plan. |
|
| 07/22/2026 | BULD - Electrical Clearance | Passed | 07/22/2026 Clearance for TEP ECO. Unit 2. |