Status:
Complete
Type:
Residential Building - One or Two Family
Apply Date:
09/09/2025
Applicant:
Chris Reynolds
Description:
REV1: Delete receptacles and modify beam Remodel, mechanical upgrades and electrical service upgrade to Unit 1 and Unit 2 of this address.

Permit Reviews

Permit Number - TC-RES-0925-04459
Permit Status: Complete
Permit Description: REV1: Delete receptacles and modify beam Remodel, mechanical upgrades and electrical service upgrade to Unit 1 and Unit 2 of this address.
Start Date Submittal Complete Date Status  
01/21/2026 RESIDENTIAL NEW DWELLING REVISION v.1 01/26/2026 REQUIRES RESUBMIT Review Details
01/30/2026 RESIDENTIAL NEW DWELLING REVISION v.2 02/11/2026 REQUIRES RESUBMIT Review Details
11/21/2025 RESIDENTIAL ADD/ALT v.3 11/21/2025 APPROVED Review Details
10/22/2025 RESIDENTIAL ADD/ALT v.2 11/18/2025 REQUIRES RESUBMIT Review Details
09/12/2025 RESIDENTIAL ADD/ALT v.1 09/12/2025 REQUIRES RESUBMIT Review Details
02/11/2026 RESIDENTIAL NEW DWELLING REVISION v.3 02/12/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0925-04459
Permit Status: Complete
Permit Description: REV1: Delete receptacles and modify beam Remodel, mechanical upgrades and electrical service upgrade to Unit 1 and Unit 2 of this address.
Date Description Comments
09/12/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0925-04459
Permite Description: REV1: Delete receptacles and modify beam Remodel, mechanical upgrades and electrical service upgrade to Unit 1 and Unit 2 of this address.
Total Outstanding Inspections - 17
Last Inspection Date Description Inspector Results Comments
12/18/2025 BULD - Electrical Clearance N/A Canceled
12/18/2025 COT - BULD - SWG Clearance N/A Canceled
12/18/2025 COT - RSEL - Electrical Underground N/A Canceled
12/18/2025 COT - RSPL - Gas Pressure Test N/A Canceled
12/19/2025 RSBU - Building Final N/A Canceled 12-19-25: canceled by contractor.
12/18/2025 RSEL - Electrical Progress N/A Canceled
12/18/2025 RSME - Mechanical Progress N/A Canceled
02/17/2026 COT - RSEL - Electrical Final N/A Re-inspection required (with fee)
02/17/2026 COT - RSME - Mechanical Final N/A Re-inspection required (with fee)
02/17/2026 COT - RSPL - Plumbing Final N/A Re-inspection required (with fee)
12/23/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 12/23/25: All construction has been completed prior to conducting any on-site inspection. Framing members shall be exposed throughout the home to verify code compliance and adherence to approved plans (this will include wall framing and ceiling framing), We shall verify holdown location on sill plate to very proper anchorage, all mechanical clips shall be exposed to verify compliance, we shall require verification of trench depth for electrical underground and plumbing pipes such as sewer lines, raceway for subpanel shall be ran underground from current location of main panel (piping shall be properly secure and meet the requirements for burial depth), AFCI and GFCI required throughout unit 1 and unit 2, multiple branch circuits missing per approved plans, receptacle spacing does not meet code, smoke alarms must be interconnected, footings and slab must be exposed around perimeter to verify proper depth and size, x-ray will be required to ensure reinforcement installed in footings, in-wall rough-ins were never called ( we shall verify all wiring/pluming/mechanical in wall), mini splits must be listed and approved for US application, receptacles required at front and rear of home, light fixtures shall meet Pima county outdoor light ordinance, All requirements of the All inclusive home design shall be met. MORE ITEMS MAY BE ADDED AT TIME OF RE-INSPECTION
12/18/2025 COT - RSBU - Interior Shear Bracing N/A Canceled
12/18/2025 COT - RSPL - Yard Water Line N/A Canceled
12/18/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Canceled
12/18/2025 COT - RSPL - Sewer N/A Canceled
12/18/2025 COT - RSPL - Rough Soil N/A Canceled
12/18/2025 RSPL - Plumbing Progress N/A Canceled

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0925-04459
Permit Description: REV1: Delete receptacles and modify beam Remodel, mechanical upgrades and electrical service upgrade to Unit 1 and Unit 2 of this address.
Total Completed Inspections - 13

Documents

File Name Document Type  
LOFC_LETTEROFCOMPLETION (SSRS).PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-2-5_S2.1_FRAMING_21.15-MODEL_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
251016_LIBERTY-UNIT 2_RESPONSE LETTER-R_V1.PDF DOCUMENTS VIEW
3450 S LIBERTY AVE CALCS UNIT 2_V2.PDF DOCUMENTS VIEW
CONS-3450 S LIBERTY- UNIT 2_V2.PDF DOCUMENTS VIEW