Permit Reviews

Permit Number - TC-RES-0924-05126
Permit Status: Inspections complete
Permit Description: SFR Unit #2
Start Date Submittal Complete Date Status  
11/05/2024 RESTAMP - RESIDENTIAL v.1 11/12/2024 APPROVED Review Details
09/18/2024 RESIDENTIAL NEW DWELLING v.1 10/17/2024 REQUIRES RESUBMIT Review Details
05/01/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 05/05/2025 APPROVED Review Details
10/24/2024 RESIDENTIAL NEW DWELLING v.2 11/05/2024 APPROVED Review Details

Conditions

Permit Number - TC-RES-0924-05126
Permit Status: Inspections complete
Permit Description: SFR Unit #2
Date Description Comments
09/23/2024 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
01/14/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
09/23/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0924-05126
Permite Description: SFR Unit #2
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
05/27/2025 COT - RSEL - Electrical Underground N/A Not Applicable
06/03/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required Missing h25 at jack truss back entry and double girder trusses throughout. Add fha plate at kitchen hood. Add nail plates to pipes and electrical lines that are less than an 1 1/4" from face of 2x. Secure pex lines throughout every 32". Add ground screws to metal boxes. Drain for laundry is creating an S trap. 6/2/2025

6.3.25:FHA plate required at kitchen hood vent, nail plate required at bathroom south east corner (marked with a red x), thermostat shall be no higher than 48" above finish floor.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0924-05126
Permit Description: SFR Unit #2
Total Completed Inspections - 14
Date Description Inspector Results Comments
03/24/2025 COT - RSPL - Rough Soil Passed Ok to cover progress areas.
04/01/2025 COT - RSBU - Preslab Passed Ensure slab is termite treated before placing concrete.
04/01/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
04/01/2025 COT - RSEL - Grounding/Bonding Passed
04/23/2025 COT - RSBU - Roof Nailing Passed
04/23/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
05/27/2025 BULD - Electrical Clearance Passed Clearance for TEP ECO. UNIT #2. 5/27/2025
06/06/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
08/04/2025 RSBU - Building Final Passed
08/04/2025 COT - RSEL - Electrical Final Passed
08/04/2025 COT - RSEL - Outdoor Lighting Passed
08/04/2025 COT - RSPL - Yard Water Line Passed
08/04/2025 COT - RSPL - Plumbing Final Passed
08/04/2025 COT - RSME - Mechanical Final Passed

Documents

File Name Document Type  
TRUSS ENGINEERING 1106 E LEE ST_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-1106 E LEE DRAWING SET REVISED 2024 10 22_V2.PDF DOCUMENTS VIEW
1106 E LEE ST SPECIAL_INSPECTION_CERTIFICATE-2024-10-23_V1.PDF DOCUMENTS VIEW