Permit: TC-RES-0923-08247
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
5340 E 8TH ST
Address NEW:
5340 E 8TH ST
Apply Date:
09/22/2023
Applicant:
JEFF STEWART
Description:
Renovate SFR & Carport and Bathroom Addition
Permit Reviews
Permit Number - TC-RES-0923-08247
Permit Status: Complete
Permit Description: Renovate SFR & Carport and Bathroom Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/14/2023 | RESIDENTIAL NEW DWELLING v.2 | 12/12/2023 | REQUIRES RESUBMIT |
| 03/06/2024 | RESIDENTIAL NEW DWELLING v.3 | 04/05/2024 | APPROVED |
| 09/26/2023 | RESIDENTIAL NEW DWELLING v.1 | 10/17/2023 | REQUIRES RESUBMIT |
| 04/05/2024 | RESTAMP - RESIDENTIAL v.1 | 04/08/2024 | APPROVED |
Conditions
Permit Number - TC-RES-0923-08247
Permit Status: Complete
Permit Description: Renovate SFR & Carport and Bathroom Addition
| Date | Description | Comments |
|---|---|---|
| 04/08/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0923-08247
Permite Description: Renovate SFR & Carport and Bathroom Addition
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/16/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Partial Pass | mechanical |
| 08/04/2025 | RSBU - Building Final | N/A | Re-inspection required | Provide address at home. Receptacles in laundry room tied into lighting and exhaust. Provide a second opening to outdoor in water heater closet. Kitchen receptacles tied into lighting circuits. Missing receptacles at kitchen island. Provide hammer arrestors for dishwasher and refrigerator. Install dishwasher at time of inspection. Provide a cooking appliance prior to final. Master bathroom receptacles tied into lighting circuits. Caulk tub. Hall bathroom has same issues. Missing receptacles for double lav. Panel not per schedule. Provide arc fault breakers at all living spaces. Provide WR receptacles for outdoors. Romex not rated for outdoor use. Provide treaded wood and coated schedule 40 pvc for condensation line. Provide a KO seal at disconnect box. 8/4/2025 |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0923-08247
Permit Description: Renovate SFR & Carport and Bathroom Addition
Total Completed Inspections - 16