Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Apply Date:
08/17/2026
Applicant:
Marco Verdugo
Description:
Replaced old pas pipelines and moved location of water heater.

Permit Reviews

Permit Number - TC-RES-0826-04572
Permit Status: Inspections
Permit Description: Replaced old pas pipelines and moved location of water heater.
Start Date Submittal Complete Date Status  
08/17/2026 RESIDENTIAL SIMPLE REVIEW v.1 08/17/2026 REQUIRES RESUBMIT Review Details
08/21/2026 RESIDENTIAL SIMPLE REVIEW v.2 08/24/2026 REQUIRES RESUBMIT Review Details
09/01/2026 RESIDENTIAL SIMPLE REVIEW v.3 09/01/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0826-04572
Permit Status: Inspections
Permit Description: Replaced old pas pipelines and moved location of water heater.
Date Description Comments
08/17/2026 Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0826-04572
Permite Description: Replaced old pas pipelines and moved location of water heater.
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
10/13/2026 COT - BULD - SWG Clearance N/A Re-inspection required 10/13/26: set gauge to 15 psi for a minimum of 10 minutes, fire foam top plate penetration at kitchen, add 4" blocks on rooftop at 6' apart, secure gas line on exterior wall, wood enclosure for gas water heater requires a pressure treated sill plates and wood enclosures must meet ventilation requirements such as louvers, missing pressure relive valve, IPS pvc is not allowed for a gas water heater-installation of copper lines is required, missing anti-tip device at range, missing vent at water heater. Stopped inspection-additional items may be noted.
10/13/2026 COT - RSPL - Plumbing Final N/A Re-inspection required 10/13/26: set gauge to 15 psi for a minimum of 10 minutes, fire foam top plate penetration at kitchen, add 4" blocks on rooftop at 6' apart, secure gas line on exterior wall, wood enclosure for gas water heater requires a pressure treated sill plates and wood enclosures must meet ventilation requirements such as louvers, missing pressure relive valve, IPS pvc is not allowed for a gas water heater-installation of copper lines is required, missing anti-tip device at range, missing vent at water heater. Stopped inspection-additional items may be noted.