Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Apply Date:
08/12/2024
Applicant:
Tina Wilson
Description:
IN GROUND POOL WITH EQUIPMENT

Permit Reviews

Permit Number - TC-RES-0824-04693
Permit Status: Inspections complete
Permit Description: IN GROUND POOL WITH EQUIPMENT
Start Date Submittal Complete Date Status  
08/13/2024 RESIDENTIAL POOL v.1 08/28/2024 APPROVED Review Details

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0824-04693
Permite Description: IN GROUND POOL WITH EQUIPMENT
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
11/29/2024 COT - BULD - SWG Clearance N/A Not Applicable 11-29-24, not applicable.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0824-04693
Permit Description: IN GROUND POOL WITH EQUIPMENT
Total Completed Inspections - 8
Date Description Inspector Results Comments
10/25/2024 Pool/Spa - Pre-Gunite Passed Rebar reinforcement is properly installed and supported off of ground, underground pipes are installed and connected to pool equipment, water line for auto-fill is installed with vacuum breaker, electrical conduit is installed for pool equipment and pool light, and bonding wire is ran completely around pool and connected to rebar and pool equipment. Okay to proceed with application of gunite for pool side and floor.
10/25/2024 Pool/Spa - Plumbing Passed Underground plumbing is complete from pool pump equipment to drain and pool bottom cleaners. Auto-fill pipe is installed with vacuum breaker at main water supply line to house, and entire system is under water pressure test.
10/25/2024 Pool/Spa - Bonding Grip Passed Bonding wire is properly connected to pool equipment and rebar reinforcement around pool.
10/25/2024 Pool/Spa - Electric Passed pool equipment control panel and GFCI receptacle are installed, conduit is installed in trench to main electrical panel, and Bonding wire is properly connected to pool equipment and rebar reinforcement around pool.
10/25/2024 RSEL - Electrical Progress Passed pool equipment control panel and GFCI receptacle are installed, conduit is installed in trench to main electrical panel, and Bonding wire is properly connected to pool equipment and rebar reinforcement around pool.
11/29/2024 RSBU - Building Final Passed 11-29-24, all code requirements for installation of swimming pool have been met. Final approved.
11/29/2024 Pool/Spa - Final/Barrier Passed 11-29-24, pool alarm system installed at back sliding glass door. System meets code requirements.
11/29/2024 COT - RSEL - Electrical Final Passed 11-29-24, electrical final for pool approved.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-SITE PLAN 340515_V1.PDF DOCUMENTS VIEW
ENGINEERING 340515_V1.PDF DOCUMENTS VIEW