Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-RES-0824-04693
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
3972 S CORTE RANA RICA
Apply Date:
08/12/2024
Applicant:
Tina Wilson
Description:
IN GROUND POOL WITH EQUIPMENT
Permit Reviews
Permit Number - TC-RES-0824-04693
Permit Status: Inspections complete
Permit Description: IN GROUND POOL WITH EQUIPMENT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/13/2024 | RESIDENTIAL POOL v.1 | 08/28/2024 | APPROVED |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0824-04693
Permite Description: IN GROUND POOL WITH EQUIPMENT
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/29/2024 | COT - BULD - SWG Clearance | N/A | Not Applicable | 11-29-24, not applicable. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0824-04693
Permit Description: IN GROUND POOL WITH EQUIPMENT
Total Completed Inspections - 8
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/25/2024 | Pool/Spa - Pre-Gunite | Passed | Rebar reinforcement is properly installed and supported off of ground, underground pipes are installed and connected to pool equipment, water line for auto-fill is installed with vacuum breaker, electrical conduit is installed for pool equipment and pool light, and bonding wire is ran completely around pool and connected to rebar and pool equipment. Okay to proceed with application of gunite for pool side and floor. | |
10/25/2024 | Pool/Spa - Plumbing | Passed | Underground plumbing is complete from pool pump equipment to drain and pool bottom cleaners. Auto-fill pipe is installed with vacuum breaker at main water supply line to house, and entire system is under water pressure test. | |
10/25/2024 | Pool/Spa - Bonding Grip | Passed | Bonding wire is properly connected to pool equipment and rebar reinforcement around pool. | |
10/25/2024 | Pool/Spa - Electric | Passed | pool equipment control panel and GFCI receptacle are installed, conduit is installed in trench to main electrical panel, and Bonding wire is properly connected to pool equipment and rebar reinforcement around pool. | |
10/25/2024 | RSEL - Electrical Progress | Passed | pool equipment control panel and GFCI receptacle are installed, conduit is installed in trench to main electrical panel, and Bonding wire is properly connected to pool equipment and rebar reinforcement around pool. | |
11/29/2024 | RSBU - Building Final | Passed | 11-29-24, all code requirements for installation of swimming pool have been met. Final approved. | |
11/29/2024 | Pool/Spa - Final/Barrier | Passed | 11-29-24, pool alarm system installed at back sliding glass door. System meets code requirements. | |
11/29/2024 | COT - RSEL - Electrical Final | Passed | 11-29-24, electrical final for pool approved. |