Permit: TC-RES-0824-04666
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
802 S FORDHAM DR
Address NEW:
802 S FORDHAM DR
Apply Date:
08/09/2024
Applicant:
Jose Gonzalez
Description:
Patio Additions and Replace HVAC New Mechanical Plan
Permit Reviews
Permit Number - TC-RES-0824-04666
Permit Status: Complete
Permit Description: Patio Additions and Replace HVAC
New Mechanical Plan
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/19/2025 | RESIDENTIAL NEW DWELLING REVISION v.2 | 05/27/2025 | APPROVED |
| 02/03/2025 | RESIDENTIAL NEW DWELLING REVISION v.2 | 03/05/2025 | APPROVED |
| 09/24/2024 | RESIDENTIAL NEW DWELLING v.2 | 09/25/2024 | REQUIRES RESUBMIT |
| 04/09/2025 | RESIDENTIAL NEW DWELLING REVISION v.1 | 04/09/2025 | REQUIRES RESUBMIT |
| 10/02/2024 | RESIDENTIAL NEW DWELLING v.3 | 10/03/2024 | APPROVED |
| 08/13/2024 | RESIDENTIAL NEW DWELLING v.1 | 09/13/2024 | REQUIRES RESUBMIT |
| 10/03/2024 | RESTAMP - RESIDENTIAL v.1 | 10/17/2024 | APPROVED |
| 01/26/2025 | RESIDENTIAL NEW DWELLING REVISION v.1 | 01/27/2025 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0824-04666
Permit Status: Complete
Permit Description: Patio Additions and Replace HVAC
New Mechanical Plan
| Date | Description | Comments |
|---|---|---|
| 10/17/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0824-04666
Permite Description: Patio Additions and Replace HVAC
New Mechanical Plan
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2024 | COT - RSBU - Roof Nailing | N/A | Not Applicable | |
| 12/09/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | nail bottom at 4” OC. |
| 12/09/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 1-Provide combustion air for water heater. 2-Provide exhaust fan in laundry. Not ready; work is not matching approved plans. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0824-04666
Permit Description: Patio Additions and Replace HVAC
New Mechanical Plan
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/20/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 2-20-25, exterior clip/sheathing together for footer depth approved. Okay to continue construction | |
| 03/14/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 3/14/25 footings at correct depth, ok to pour concrete | |
| 03/25/2025 | COT - BULD - SWG Clearance | Passed | 25 March 25 SOUTHWEST GAS CLEARANCE: SWG |
|
| 03/25/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 03/25/2025 | COT - RSEL - Electrical Final | Passed | ||
| 03/25/2025 | COT - RSEL - Outdoor Lighting | Passed | ||
| 03/25/2025 | COT - RSME - Mechanical Final | Passed | ||
| 03/25/2025 | RSBU - Building Final | Passed |