Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
6742 E CALLE LUNA
Apply Date:
08/08/2024
Applicant:
Heather McInnis
Description:
Interior repipe of existing home.

Permit Reviews

Permit Number - TC-RES-0824-04634
Permit Status: Complete
Permit Description: Interior repipe of existing home.
Start Date Submittal Complete Date Status  
08/08/2024 RESIDENTIAL SIMPLE REVIEW v.1 08/08/2024 APPROVED Review Details

Conditions

Permit Number - TC-RES-0824-04634
Permit Status: Complete
Permit Description: Interior repipe of existing home.
Date Description Comments
08/08/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0824-04634
Permite Description: Interior repipe of existing home.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
11/26/2024 RSPL - Plumbing Progress N/A Re-inspection required All pex lines in attic new to be secured every 32” and insulated. replace top plate that has been over notched in first bathroom. fire toma all top penetrations. add backing to pex lines to secure in place. separate copper lines in laundry room and secure them in place. remove zip ties. provide hammer arrestors for dishwasher, washer and ice maker. provide vacuum breakers at hose bibs. provide 18” of copper at main water line before transitioning into pex. add nail plates to any stud that is less than an 1 1/4” from pex. 11/26/2024

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0824-04634
Permit Description: Interior repipe of existing home.
Total Completed Inspections - 2
Date Description Inspector Results Comments
02/20/2025 RSPL - Plumbing Progress Passed
03/27/2025 COT - RSPL - Plumbing Final Passed 3-27-25, I previously inspected site on 2-20-25 and verified that all noted items from original inspection on 11-26-24 had been corrected. Upon arriving this morning, customer stood at his front door and stated that all work had already been covered. When asked if there were any issues with the repairs he stated that everything was in working condition.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
6742 E CALLE LUNA REPIPE IMAGE_240808_112643_V1.PDF DOCUMENTS VIEW