Permit: TC-RES-0824-04634
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
6742 E CALLE LUNA
Address NEW:
6742 E CALLE LUNA
Apply Date:
08/08/2024
Applicant:
Heather McInnis
Description:
Interior repipe of existing home.
Permit Reviews
Permit Number - TC-RES-0824-04634
Permit Status: Complete
Permit Description: Interior repipe of existing home.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/08/2024 | RESIDENTIAL SIMPLE REVIEW v.1 | 08/08/2024 | APPROVED |
Conditions
Permit Number - TC-RES-0824-04634
Permit Status: Complete
Permit Description: Interior repipe of existing home.
| Date | Description | Comments |
|---|---|---|
| 08/08/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0824-04634
Permite Description: Interior repipe of existing home.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/26/2024 | RSPL - Plumbing Progress | N/A | Re-inspection required | All pex lines in attic new to be secured every 32” and insulated. replace top plate that has been over notched in first bathroom. fire toma all top penetrations. add backing to pex lines to secure in place. separate copper lines in laundry room and secure them in place. remove zip ties. provide hammer arrestors for dishwasher, washer and ice maker. provide vacuum breakers at hose bibs. provide 18” of copper at main water line before transitioning into pex. add nail plates to any stud that is less than an 1 1/4” from pex. 11/26/2024 |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0824-04634
Permit Description: Interior repipe of existing home.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/20/2025 | RSPL - Plumbing Progress | Passed | ||
| 03/27/2025 | COT - RSPL - Plumbing Final | Passed | 3-27-25, I previously inspected site on 2-20-25 and verified that all noted items from original inspection on 11-26-24 had been corrected. Upon arriving this morning, customer stood at his front door and stated that all work had already been covered. When asked if there were any issues with the repairs he stated that everything was in working condition. |