Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0824-04634

Parcel: 135060560


Addresses:

6742 E CALLE LUNA

Inspection Status: Passed

Inspection History: RSPL - Plumbing Progress

Date Description Inspector Results Comments
02/20/2025 RSPL - Plumbing Progress Passed
11/26/2024 RSPL - Plumbing Progress Re-inspection required All pex lines in attic new to be secured every 32” and insulated. replace top plate that has been over notched in first bathroom. fire toma all top penetrations. add backing to pex lines to secure in place. separate copper lines in laundry room and secure them in place. remove zip ties. provide hammer arrestors for dishwasher, washer and ice maker. provide vacuum breakers at hose bibs. provide 18” of copper at main water line before transitioning into pex. add nail plates to any stud that is less than an 1 1/4” from pex. 11/26/2024