Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-RES-0823-07092
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
326 E 17TH ST UNIT 2
Address NEW:
326 E 17TH ST UNIT 2
Apply Date:
08/07/2023
Applicant:
Jeffrey Adragna
Description:
ADU
Permit Reviews
Permit Number - TC-RES-0823-07092
Permit Status: Inspections
Permit Description: ADU
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/31/2024 | RESIDENTIAL NEW DWELLING v.1 | 01/02/2025 | REQUIRES RESUBMIT |
| 03/05/2025 | RESIDENTIAL NEW DWELLING v.3 | 03/06/2025 | APPROVED |
| 08/30/2023 | RESIDENTIAL NEW DWELLING v.1 | 08/30/2023 | REQUIRES RESUBMIT |
| 01/31/2025 | RESIDENTIAL NEW DWELLING v.2 | 03/04/2025 | REQUIRES RESUBMIT |
| 06/27/2024 | RESIDENTIAL NEW DWELLING v.3 | 07/19/2024 | APPROVED |
| 08/31/2023 | RESIDENTIAL NEW DWELLING v.2 | 10/03/2023 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-RES-0823-07092
Permit Status: Inspections
Permit Description: ADU
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/22/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-RES-0823-07092
Permit Status: Inspections
Permit Description: ADU
| Date | Description | Comments |
|---|---|---|
| 09/18/2023 | Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0823-07092
Permite Description: ADU
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 6/9/25: Missing anchor bolt in kitchen/living room (12" from edge of sill plate), tighten anchor bolt at kitchen/living room south wall (marked with red marker), Hangers are not properly fastened at trusses (fasteners required throughout), fastener spacing at exterior sheathing not per plan, fasteners shall be no closer than 3/8" from edge's and shall penetrate no more than 1/8". |
| 06/09/2025 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 5/9/26: loose sheathing at north SW corner/ NE corner/ SE corner. Truss clacs required for roof nail inspection. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0823-07092
Permit Description: ADU
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/30/2025 | COT - RSPL - Rough Soil | Passed | Ok to cover progress area | |
| 05/06/2025 | COT - RSBU - Preslab | Passed | Ensure slab area is termite treated before placing concrete. | |
| 05/06/2025 | COT - RSEL - Grounding/Bonding | Passed | ||
| 06/11/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 06/11/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 06/11/2025 | COT - RSBU - Roof Nailing | Passed | Ok to dry-in roof system. | |
| 06/16/2025 | BULD - Electrical Clearance | Passed | Ok to set meter and begin new service. | |
| 06/16/2025 | COT - RSEL - Electrical Underground | Passed | ||
| 08/04/2025 | COT - RSPL - Yard Water Line | Passed | Ok to cover progress areas. | |
| 08/11/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Ok to insulate and sheet rock throughout |