Permit: TC-RES-0823-07084
Permit Details
Apply Date:
08/04/2023
Applicant:
Carol Estrada
Description:
we are going to replace a mobile home for a manufacture home.
Permit Reviews
Permit Number - TC-RES-0823-07084
Permit Status: Issued
Permit Description: we are going to replace a mobile home for a manufacture home.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/07/2023 | RESIDENTIAL NEW DWELLING v.1 | 08/17/2023 | APPROVED |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-RES-0823-07084
Permite Description: we are going to replace a mobile home for a manufacture home.
Total Outstanding Inspections - 16
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2023 | COT - RSPL - Rough Soil | N/A | Not Applicable | |
09/26/2023 | COT - RSPL - Sewer | N/A | Not Applicable | |
09/26/2023 | COT - RSPL - Yard Water Line | N/A | Not Applicable | |
09/26/2023 | RSEL - Electrical Progress | N/A | Not Applicable | |
09/26/2023 | RSME - Mechanical Progress | N/A | Not Applicable | |
09/26/2023 | RSPL - Plumbing Progress | N/A | Not Applicable | |
09/26/2023 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
09/26/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Not Applicable | |
09/26/2023 | COT - RSBU - Preslab | N/A | Not Applicable | |
09/26/2023 | COT - RSBU - Interior Shear Bracing | N/A | Not Applicable | |
09/26/2023 | COT - RSBU - Exterior Clips/Sheathing | N/A | Not Applicable | |
09/26/2023 | COT - BULD - SWG Clearance | N/A | Re-inspection required | 1-Test gauge does not show tenths of a pound per IPC 312.1.1. |
09/26/2023 | COT - RSPL - Gas Pressure Test | N/A | Re-inspection required | 1-Test gauge does not show tenths of a pound per IPC 312.1.1. |
09/26/2023 | BULD - Electrical Clearance | N/A | Re-inspection required | 1-ground rods are less than 6' apart. |
10/05/2023 | COT - RSMH - Mobile/Mod Home Final | N/A | Re-inspection required (with fee) | 9/28/23: HVAC unit not installed. 9/28/23:1-Rear setback is 4' 5" to adjacent mobile; no drive as shown on plans. 2-Front setback is 5' to drive; plans shows 6'. 10/3/23: revise plans to reflect placement of mobile home 10/4/2023 awning not per plans. Provide a set of approved plans to the site . Awning is being constructed, provide scope of footings. Trenches are still open gas and electrical needs too be green tagged. 10/5/23: awning not per plans. Provide a set of approved plans to the site . Awning is being constructed, provide scope of footings. Trenches are still open gas and electrical needs too be green tagged. AC units needs lock out caps on refrigerant lines. |
10/05/2023 | RSBU - Building Final | N/A | Re-inspection required (with fee) | 9/28/23: HVAC unit not installed. 9/28/23:1-Rear setback is 4' 5" to adjacent mobile; no drive as shown on plans. 2-Front setback is 5' to drive; plans shows 6'. 10/3/23: revise plans to reflect placement of mobile home 10/4/2023 awning not per plans. Provide a set of approved plans to the site . Awning is being constructed, provide scope of footings. Trenches are still open gas and electrical needs too be green tagged. 10/5/23: awning not per plans. Provide a set of approved plans to the site . Awning is being constructed, provide scope of footings. Trenches are still open gas and electrical needs too be green tagged. AC units needs lock out caps on refrigerant lines. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-RES-0823-07084
Permit Description: we are going to replace a mobile home for a manufacture home.
Total Completed Inspections - 3
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/27/2023 | COT - BULD - SWG Clearance | Passed | Approved pressure test, SWG Clearance is required for MH unit #43D | |
09/27/2023 | COT - RSPL - Gas Pressure Test | Passed | ||
09/28/2023 | BULD - Electrical Clearance | Passed | 1-ground rods are less than 6' apart. 9/27/23 - Approved private MH pedestal unit #43D. No clearance is required on a master meter |