Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
08/04/2023
Applicant:
Carol Estrada
Description:
we are going to replace a mobile home for a manufacture home.

Permit Reviews

Permit Number - TC-RES-0823-07084
Permit Status: Issued
Permit Description: we are going to replace a mobile home for a manufacture home.
Start Date Submittal Complete Date Status  
08/07/2023 RESIDENTIAL NEW DWELLING v.1 08/17/2023 APPROVED Review Details

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-RES-0823-07084
Permite Description: we are going to replace a mobile home for a manufacture home.
Total Outstanding Inspections - 16
Last Inspection Date Description Inspector Results Comments
09/26/2023 COT - RSPL - Rough Soil N/A Not Applicable
09/26/2023 COT - RSPL - Sewer N/A Not Applicable
09/26/2023 COT - RSPL - Yard Water Line N/A Not Applicable
09/26/2023 RSEL - Electrical Progress N/A Not Applicable
09/26/2023 RSME - Mechanical Progress N/A Not Applicable
09/26/2023 RSPL - Plumbing Progress N/A Not Applicable
09/26/2023 COT - RSEL - Electrical Underground N/A Not Applicable
09/26/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Not Applicable
09/26/2023 COT - RSBU - Preslab N/A Not Applicable
09/26/2023 COT - RSBU - Interior Shear Bracing N/A Not Applicable
09/26/2023 COT - RSBU - Exterior Clips/Sheathing N/A Not Applicable
09/26/2023 COT - BULD - SWG Clearance N/A Re-inspection required 1-Test gauge does not show tenths of a pound per IPC 312.1.1.
09/26/2023 COT - RSPL - Gas Pressure Test N/A Re-inspection required 1-Test gauge does not show tenths of a pound per IPC 312.1.1.
09/26/2023 BULD - Electrical Clearance N/A Re-inspection required 1-ground rods are less than 6' apart.
10/05/2023 COT - RSMH - Mobile/Mod Home Final N/A Re-inspection required (with fee) 9/28/23: HVAC unit not installed.

9/28/23:1-Rear setback is 4' 5" to adjacent mobile; no drive as shown on plans. 2-Front setback is 5' to drive; plans shows 6'.

10/3/23: revise plans to reflect placement of mobile home

10/4/2023 awning not per plans. Provide a set of approved plans to the site . Awning is being constructed, provide scope of footings. Trenches are still open gas and electrical needs too be green tagged.

10/5/23: awning not per plans. Provide a set of approved plans to the site . Awning is being constructed, provide scope of footings. Trenches are still open gas and electrical needs too be green tagged. AC units needs lock out caps on refrigerant lines.
10/05/2023 RSBU - Building Final N/A Re-inspection required (with fee) 9/28/23: HVAC unit not installed.

9/28/23:1-Rear setback is 4' 5" to adjacent mobile; no drive as shown on plans. 2-Front setback is 5' to drive; plans shows 6'.

10/3/23: revise plans to reflect placement of mobile home

10/4/2023 awning not per plans. Provide a set of approved plans to the site . Awning is being constructed, provide scope of footings. Trenches are still open gas and electrical needs too be green tagged.

10/5/23: awning not per plans. Provide a set of approved plans to the site . Awning is being constructed, provide scope of footings. Trenches are still open gas and electrical needs too be green tagged. AC units needs lock out caps on refrigerant lines.

Completed Inspections

Permit Status: Issued
Permit Number: TC-RES-0823-07084
Permit Description: we are going to replace a mobile home for a manufacture home.
Total Completed Inspections - 3
Date Description Inspector Results Comments
09/27/2023 COT - BULD - SWG Clearance Passed Approved pressure test, SWG Clearance is required for MH unit #43D
09/27/2023 COT - RSPL - Gas Pressure Test Passed
09/28/2023 BULD - Electrical Clearance Passed 1-ground rods are less than 6' apart.
9/27/23 - Approved private MH pedestal unit #43D. No clearance is required on a master meter

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-NEW DOCUMENT(23) 04-AUG-2023 19-36-16(1)_V1.PDF DOCUMENTS VIEW
NEW DOCUMENT(17) 20-JUN-2023 10-34-46_V1.PDF DOCUMENTS VIEW