Permit: TC-RES-0726-03665
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
7451 E LAKESIDE DR
Address NEW:
7451 E LAKESIDE DR
Apply Date:
07/06/2026
Applicant:
Billy Meyer
Description:
repair of damaged carport to its original configuration
Permit Reviews
Permit Number - TC-RES-0726-03665
Permit Status: Inspections
Permit Description: repair of damaged carport to its original configuration
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/08/2026 | RESIDENTIAL ADD/ALT v.1 | 07/20/2026 | APPROVED |
Conditions
Permit Number - TC-RES-0726-03665
Permit Status: Inspections
Permit Description: repair of damaged carport to its original configuration
| Date | Description | Comments |
|---|---|---|
| 07/20/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0726-03665
Permite Description: repair of damaged carport to its original configuration
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/28/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Partial Pass | |
| 10/29/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 1. About 75% of the sheating has been rained on and are delaminating or have lost structural integrity and over driven nails have added insult to injury. 2. Nails driven to close to edges of panels and have caused edge blow or splitting on some rafters. Should be 3/8" minimum from edges 3. Over driven nails on majority of sheating crushing wood fibers. Nails should sit flush with sheating or no more than 1/16". 4. Remove and replace damaged sheathing; correct sheating spacing, add properly coated ring shank roof nails. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0726-03665
Permit Description: repair of damaged carport to its original configuration
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 10/09/2026 Added footer per plan, okay to pour. |
|
| 10/29/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |