Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
1701 S VIA HONDO
Address NEW:
1701 S VIA HONDO
Apply Date:
07/08/2025
Applicant:
alex enoch
Description:
Repair SFR and Replace Porch from Fire Damage and Bathroom Addition

Permit Reviews

Permit Number - TC-RES-0725-03421
Permit Status: Inspections complete
Permit Description: Repair SFR and Replace Porch from Fire Damage and Bathroom Addition
Start Date Submittal Complete Date Status  
12/08/2025 RESIDENTIAL NEW DWELLING REVISION v.1 12/23/2025 APPROVED Review Details
07/11/2025 RESIDENTIAL ADD/ALT v.1 08/07/2025 REQUIRES RESUBMIT Review Details
08/13/2025 RESTAMP - RESIDENTIAL v.1 08/13/2025 APPROVED Review Details
08/12/2025 RESIDENTIAL ADD/ALT v.2 08/13/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-0725-03421
Permit Status: Inspections complete
Permit Description: Repair SFR and Replace Porch from Fire Damage and Bathroom Addition
Date Description Comments
07/11/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0725-03421
Permite Description: Repair SFR and Replace Porch from Fire Damage and Bathroom Addition
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
03/13/2026 COT - RSPL - Rough Soil N/A Re-inspection required 3-13-26: spoke with point of contact at 1210 and advised him I'd be on site in 45 minutes. Arrived on site at approximately 1255 hours, waited 10 minutes and left due to schedule/time constraints. Please reschedule.
01/02/2026 COT - RSBU - Excavation/Rebar/Zoning N/A Partial Pass Partial pass. Total of 3 post column footers for front porch. Reinforcements, depth along with the width are per plan. Okay for concrete placement. 1/2/2025
08/28/2026 COT - RSPL - Gas Pressure Test N/A Not Applicable
08/28/2026 COT - BULD - SWG Clearance N/A Not Applicable

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0725-03421
Permit Description: Repair SFR and Replace Porch from Fire Damage and Bathroom Addition
Total Completed Inspections - 9
Date Description Inspector Results Comments
12/16/2025 BULD - Electrical Clearance Passed 12.16.25
approved for INCR
01/02/2026 COT - RSBU - Roof Nailing Passed
03/17/2026 COT - RSPL - Rough Soil Passed 3.17.26
Approved, ok to backfill
04/30/2026 COT - RSBU - Excavation/Rebar/Zoning Passed
05/04/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 5.4.26
Corrections made and verified. Proceed.
08/28/2026 RSBU - Building Final Passed Passed
08/28/2026 COT - RSPL - Plumbing Final Passed Passed
08/28/2026 COT - RSME - Mechanical Final Passed Passed
08/28/2026 COT - RSEL - Electrical Final Passed Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-REV PLAN SET V1_V1.PDF DOCUMENTS VIEW
REVISION NARRATIVE_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-PLAN SET V2_V2.PDF DOCUMENTS VIEW