Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
730 N CAMINO SANTIAGO
Apply Date:
07/19/2023
Applicant:
Elizabeth Sykes
Description:
IN GROUND POOL WITH EQUIPMENT

Permit Reviews

Permit Number - TC-RES-0723-06667
Permit Status: Complete
Permit Description: IN GROUND POOL WITH EQUIPMENT
Start Date Submittal Complete Date Status  
08/08/2023 RESTAMP - RESIDENTIAL v.1 08/10/2023 APPROVED Review Details
07/24/2023 RESIDENTIAL NEW DWELLING v.1 07/27/2023 REQUIRES RESUBMIT Review Details
08/04/2023 RESIDENTIAL NEW DWELLING v.2 08/08/2023 APPROVED Review Details

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0723-06667
Permite Description: IN GROUND POOL WITH EQUIPMENT
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/16/2023 COT - BULD - SWG Clearance N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0723-06667
Permit Description: IN GROUND POOL WITH EQUIPMENT
Total Completed Inspections - 8
Date Description Inspector Results Comments
09/20/2023 Pool/Spa - Bonding Grip Passed Continuous ground wire is ran from pool pump location around pool deck and connected at 4 locations on the rebar reinforcement. Rebar reinforcement is properly installed and wired off with concrete dobbies holding it up off the ground. Electrical conduit for pool light is in place within the trench. Okay to apply gunite to pool bottom and sides.
09/20/2023 Pool/Spa - Pre-Gunite Passed Continuous ground wire is ran from pool pump location around pool deck and connected at 4 locations on the rebar reinforcement. Rebar reinforcement is properly installed and wired off with concrete dobbies holding it up off the ground. Electrical conduit for pool light is in place within the trench. Okay to apply gunite to pool bottom and sides.
10/16/2023 Pool/Spa - Final/Barrier Passed
10/16/2023 COT - RSEL - Electrical Final Passed
10/16/2023 Pool/Spa - Electric Passed
10/16/2023 Pool/Spa - Plumbing Passed
10/16/2023 RSBU - Building Final Passed
10/16/2023 RSEL - Electrical Progress Passed

Documents

File Name Document Type  
LOFC_LETTEROFCOMPLETION.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CORRECTED SITE PLAN 330523 MOGA1_V2.PDF DOCUMENTS VIEW