Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Address:
226 E NAVAJO RD
Address NEW:
226 E NAVAJO RD
Apply Date:
07/10/2023
Applicant:
Rich Coyle
Description:
We will tunnel under the back fence and excavate 40' trench from the fence to the back Southside of the house. We will install new 1 1/4" P.E gas pipe with steel raiser from the meter to the house. We will install a new 1/4 turn isolation valve on the riser at the house. We will then run new appropriately sized pipe up and across the roof to three fixtures (1-furnace, 1 water heater, and 1 range) We will install new gas shut offs and gas flex supplies on all fixtures. There will be 3 roof penetrations on all fixtures which will be properly sealed. Work will require cutting open the drywall behind the stove to run new gas line down the wall to the stove. All pipe on the roof and wall will be properly strapped and secured. We may also need to cut a hole in the ceiling to get into the crawl space between the ceiling and the roof in order to drill holes.

Permit Reviews

Permit Number - TC-RES-0723-06411
Permit Status: Issued
Permit Description: We will tunnel under the back fence and excavate 40' trench from the fence to the back Southside of the house. We will install new 1 1/4" P.E gas pipe with steel raiser from the meter to the house. We will install a new 1/4 turn isolation valve on the riser at the house. We will then run new appropriately sized pipe up and across the roof to three fixtures (1-furnace, 1 water heater, and 1 range) We will install new gas shut offs and gas flex supplies on all fixtures. There will be 3 roof penetrations on all fixtures which will be properly sealed. Work will require cutting open the drywall behind the stove to run new gas line down the wall to the stove. All pipe on the roof and wall will be properly strapped and secured. We may also need to cut a hole in the ceiling to get into the crawl space between the ceiling and the roof in order to drill holes.
Start Date Submittal Complete Date Status  
07/10/2023 RESIDENTIAL SIMPLE REVIEW v.1 07/11/2023 APPROVED Review Details

Conditions

Permit Number - TC-RES-0723-06411
Permit Status: Issued
Permit Description: We will tunnel under the back fence and excavate 40' trench from the fence to the back Southside of the house. We will install new 1 1/4" P.E gas pipe with steel raiser from the meter to the house. We will install a new 1/4 turn isolation valve on the riser at the house. We will then run new appropriately sized pipe up and across the roof to three fixtures (1-furnace, 1 water heater, and 1 range) We will install new gas shut offs and gas flex supplies on all fixtures. There will be 3 roof penetrations on all fixtures which will be properly sealed. Work will require cutting open the drywall behind the stove to run new gas line down the wall to the stove. All pipe on the roof and wall will be properly strapped and secured. We may also need to cut a hole in the ceiling to get into the crawl space between the ceiling and the roof in order to drill holes.
Date Description Comments
07/12/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit.

Completed Inspections

Permit Status: Issued
Permit Number: TC-RES-0723-06411
Permit Description: We will tunnel under the back fence and excavate 40' trench from the fence to the back Southside of the house. We will install new 1 1/4" P.E gas pipe with steel raiser from the meter to the house. We will install a new 1/4 turn isolation valve on the riser at the house. We will then run new appropriately sized pipe up and across the roof to three fixtures (1-furnace, 1 water heater, and 1 range) We will install new gas shut offs and gas flex supplies on all fixtures. There will be 3 roof penetrations on all fixtures which will be properly sealed. Work will require cutting open the drywall behind the stove to run new gas line down the wall to the stove. All pipe on the roof and wall will be properly strapped and secured. We may also need to cut a hole in the ceiling to get into the crawl space between the ceiling and the roof in order to drill holes.
Total Completed Inspections - 3
Date Description Inspector Results Comments
08/08/2023 COT - RSPL - Plumbing Final Passed
08/08/2023 COT - RSPL - Rough Soil Passed
08/08/2023 COT - BULD - SWG Clearance Passed SWG for meter connection

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
NAVAJO[17510]_V1.PDF DOCUMENTS VIEW