Permit: TC-RES-0626-03517
Permit Details
Status:
Withdrawn
Type:
Residential Building - One or Two Family
Address:
2624 N TERESA LN
Address NEW:
2624 N TERESA LN
Apply Date:
06/28/2026
Applicant:
Austin Sanchez
Description:
Bathroom vanity leak escalated to whole house sewer liner, slab work for broken pipe, clean outs installed. Asked for permit information they told me they didnt need one its not required. We need working sewer pipes and there's a lot of money on the line
Permit Reviews
Permit Number - TC-RES-0626-03517
Permit Status: Withdrawn
Permit Description: Bathroom vanity leak escalated to whole house sewer liner, slab work for broken pipe, clean outs installed. Asked for permit information they told me they didnt need one its not required. We need working sewer pipes and there's a lot of money on the line
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/29/2026 | RESIDENTIAL SIMPLE REVIEW v.2 | 06/29/2026 | APPROVED |
| 06/29/2026 | RESIDENTIAL SIMPLE REVIEW v.1 | 06/29/2026 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0626-03517
Permit Status: Withdrawn
Permit Description: Bathroom vanity leak escalated to whole house sewer liner, slab work for broken pipe, clean outs installed. Asked for permit information they told me they didnt need one its not required. We need working sewer pipes and there's a lot of money on the line
| Date | Description | Comments |
|---|---|---|
| 06/29/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Withdrawn
Permit Number: TC-RES-0626-03517
Permite Description: Bathroom vanity leak escalated to whole house sewer liner, slab work for broken pipe, clean outs installed. Asked for permit information they told me they didnt need one its not required. We need working sewer pipes and there's a lot of money on the line
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2026 | COT - RSPL - Sewer | N/A | Re-inspection required | 7/1/26: All work completed prior to inspections. Completed work must be exposed for inspections and pressure test required on repair, relining of existing building sewer and building drain requires appropriate permits with appropriate inspections. Before work is done piping must be descaled and cleaned and Video recording is required to be shown to inspector to determine if piping system is able to be relined in accordance with manufacturer installation requirements, please read through section 717 of the 2024 IPC or the 2024 IRC section P3011. Re-inspection required. |
| 07/02/2026 | COT - RSPL - Plumbing Final | N/A | Not Ready | See previous inspection write ups |