Inspection Status: Re-inspection required
Inspection History: COT - RSPL - SewerÂ
| Date |
Description |
Inspector |
Results |
Comments |
| 07/01/2026 |
COT - RSPL - Sewer |
|
Re-inspection required |
7/1/26: All work completed prior to inspections. Completed work must be exposed for inspections and pressure test required on repair, relining of existing building sewer and building drain requires appropriate permits with appropriate inspections. Before work is done piping must be descaled and cleaned and Video recording is required to be shown to inspector to determine if piping system is able to be relined in accordance with manufacturer installation requirements, please read through section 717 of the 2024 IPC or the 2024 IRC section P3011. Re-inspection required. |