Permit: TC-RES-0626-03194
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
9014 E LAURIE ANN DR
Address NEW:
9014 E LAURIE ANN DR
Apply Date:
06/15/2026
Applicant:
Jai Walker
Description:
CONDENSER#1 TONS: 4 ACTION: CHANGEOUT LOCATION: BACK YARD SEER RATING: 15 MAKE: GOODMAN MODEL: GLXS5BA4810 NEED ELE: NO INDOOR COIL#1 TONS: 4 SEER RATING: 15 MAKE: GOODMAN MODEL: CHPTA4830C3 FURNACE#1 BTUS: 80 ACTION: CHANGEOUT LOCATION: ATTIC HEATER AFUE: 80 MAKE: GOODMAN MODEL: GRVT800805CN NEED GAS: NO NEED ELE: NO
Permit Reviews
Permit Number - TC-RES-0626-03194
Permit Status: Inspections
Permit Description: CONDENSER#1
TONS: 4
ACTION: CHANGEOUT
LOCATION: BACK YARD
SEER RATING: 15
MAKE: GOODMAN
MODEL: GLXS5BA4810
NEED ELE: NO
INDOOR COIL#1
TONS: 4
SEER RATING: 15
MAKE: GOODMAN
MODEL: CHPTA4830C3
FURNACE#1
BTUS: 80
ACTION: CHANGEOUT
LOCATION: ATTIC
HEATER AFUE: 80
MAKE: GOODMAN
MODEL: GRVT800805CN
NEED GAS: NO
NEED ELE: NO
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/15/2026 | RESIDENTIAL SIMPLE REVIEW v.1 | 06/15/2026 | APPROVED |
Conditions
Permit Number - TC-RES-0626-03194
Permit Status: Inspections
Permit Description: CONDENSER#1
TONS: 4
ACTION: CHANGEOUT
LOCATION: BACK YARD
SEER RATING: 15
MAKE: GOODMAN
MODEL: GLXS5BA4810
NEED ELE: NO
INDOOR COIL#1
TONS: 4
SEER RATING: 15
MAKE: GOODMAN
MODEL: CHPTA4830C3
FURNACE#1
BTUS: 80
ACTION: CHANGEOUT
LOCATION: ATTIC
HEATER AFUE: 80
MAKE: GOODMAN
MODEL: GRVT800805CN
NEED GAS: NO
NEED ELE: NO
| Date | Description | Comments |
|---|---|---|
| 06/15/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0626-03194
Permite Description: CONDENSER#1
TONS: 4
ACTION: CHANGEOUT
LOCATION: BACK YARD
SEER RATING: 15
MAKE: GOODMAN
MODEL: GLXS5BA4810
NEED ELE: NO
INDOOR COIL#1
TONS: 4
SEER RATING: 15
MAKE: GOODMAN
MODEL: CHPTA4830C3
FURNACE#1
BTUS: 80
ACTION: CHANGEOUT
LOCATION: ATTIC
HEATER AFUE: 80
MAKE: GOODMAN
MODEL: GRVT800805CN
NEED GAS: NO
NEED ELE: NO
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/13/2026 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 8-13-26: replace double pole 60 amp breaker to a 40amp at main panel, add a support to exhaust, and correct refrigerant copper line leak at unit in attic. |