Permit: TC-RES-0625-03173
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
4235 E CIELO AZUL
Address NEW:
4235 E CIELO AZUL
Apply Date:
06/23/2025
Applicant:
GGV Designs
Description:
Bedroom Suite Addition
Permit Reviews
Permit Number - TC-RES-0625-03173
Permit Status: Inspections
Permit Description: Bedroom Suite Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/24/2025 | RESIDENTIAL ADD/ALT v.1 | 07/24/2025 | REQUIRES RESUBMIT |
| 07/25/2025 | RESIDENTIAL ADD/ALT v.2 | 08/25/2025 | APPROVED |
| 08/25/2025 | RESTAMP - RESIDENTIAL v.1 | 08/25/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-0625-03173
Permit Status: Inspections
Permit Description: Bedroom Suite Addition
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/25/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-RES-0625-03173
Permit Status: Inspections
Permit Description: Bedroom Suite Addition
| Date | Description | Comments |
|---|---|---|
| 06/24/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0625-03173
Permite Description: Bedroom Suite Addition
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 6-9-26: add straps to DWV at 4' intervals, add stud shoe to 2x6 studs at south lavatory wall, add Boca plate at DWV where closer than 1 1/4" from edges of studs, submit a revision for mechanical-plans show a mini-split and flex was installed, a 12" clearance between pex & can lights is required- block using osb, plywood, drywall or relocate pex lines allowing for 1' clearance, hot pex lines must be insulated with R3, open knockouts at above ceiling junction boxes, add plastic bushing to protect awg wires stemming into junction boxes, add supports to restroom exhaust. Stopped inspection-additional items may be noted. |
| 06/09/2026 | COT - RSPL - Rough Soil | N/A | Partial Pass | 6-9-26: underground plumbing approved. Okay to backfill progress areas using shading materials. Note: a shower liner test will be required at shower. |
| 06/09/2026 | COT - RSEL - Outdoor Lighting | N/A | Not Ready | 6-9-26: not ready. |
| 06/09/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 6-9-26: roof at new addition was already shingled. A letter from a licensed contractor must be submitted to the city for review/approval. The letter must document that nailing at roof was installed per plans and meets the 2024 IRC. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0625-03173
Permit Description: Bedroom Suite Addition
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Passed 4/21/26 | |
| 05/27/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 06/08/2026 | COT - RSBU - Preslab | Passed | Passed | |
| 06/22/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 06/22/2206 Corrections made to prior inspection, walked rest of addition. |
|
| 06/22/2026 | COT - RSPL - Rough Soil | Passed | 06/22/2026 Holding under test. Okay to backfill. |
|
| 10/06/2026 | COT - RSEL - Outdoor Lighting | Passed |