Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address NEW:
4235 E CIELO AZUL
Apply Date:
06/23/2025
Applicant:
GGV Designs
Description:
Bedroom Suite Addition

Permit Reviews

Permit Number - TC-RES-0625-03173
Permit Status: Inspections
Permit Description: Bedroom Suite Addition
Start Date Submittal Complete Date Status  
06/24/2025 RESIDENTIAL ADD/ALT v.1 07/24/2025 REQUIRES RESUBMIT Review Details
07/25/2025 RESIDENTIAL ADD/ALT v.2 08/25/2025 APPROVED Review Details
08/25/2025 RESTAMP - RESIDENTIAL v.1 08/25/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0625-03173
Permit Status: Inspections
Permit Description: Bedroom Suite Addition
Total Outstanding Activity Conditions - 1
Date Name
08/25/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-0625-03173
Permit Status: Inspections
Permit Description: Bedroom Suite Addition
Date Description Comments
06/24/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0625-03173
Permite Description: Bedroom Suite Addition
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
06/09/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 6-9-26: add straps to DWV at 4' intervals, add stud shoe to 2x6 studs at south lavatory wall, add Boca plate at DWV where closer than 1 1/4" from edges of studs, submit a revision for mechanical-plans show a mini-split and flex was installed, a 12" clearance between pex & can lights is required- block using osb, plywood, drywall or relocate pex lines allowing for 1' clearance, hot pex lines must be insulated with R3, open knockouts at above ceiling junction boxes, add plastic bushing to protect awg wires stemming into junction boxes, add supports to restroom exhaust. Stopped inspection-additional items may be noted.
06/09/2026 COT - RSPL - Rough Soil N/A Partial Pass 6-9-26: underground plumbing approved. Okay to backfill progress areas using shading materials.
Note: a shower liner test will be required at shower.
06/09/2026 COT - RSEL - Outdoor Lighting N/A Not Ready 6-9-26: not ready.
06/09/2026 COT - RSBU - Roof Nailing N/A Re-inspection required 6-9-26: roof at new addition was already shingled. A letter from a licensed contractor must be submitted to the city for review/approval. The letter must document that nailing at roof was installed per plans and meets the 2024 IRC.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0625-03173
Permit Description: Bedroom Suite Addition
Total Completed Inspections - 6
Date Description Inspector Results Comments
04/21/2026 COT - RSBU - Excavation/Rebar/Zoning Passed Passed 4/21/26
05/27/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
06/08/2026 COT - RSBU - Preslab Passed Passed
06/22/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 06/22/2206
Corrections made to prior inspection, walked rest of addition.
06/22/2026 COT - RSPL - Rough Soil Passed 06/22/2026
Holding under test. Okay to backfill.
10/06/2026 COT - RSEL - Outdoor Lighting Passed

Documents

File Name Document Type  
CIELO AZUL ROOFING LETTER_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-2_PLANS_2025.46_KSW CIELO AZUL_V2.PDF DOCUMENTS VIEW