Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address NEW:
5849 S 6TH AV UNIT 3
Apply Date:
06/02/2025
Applicant:
Oscar Juarez
Description:
ADU

Permit Reviews

Permit Number - TC-RES-0625-02831
Permit Status: Inspections
Permit Description: ADU
Start Date Submittal Complete Date Status  
10/22/2025 RESIDENTIAL NEW DWELLING v.2 11/06/2025 APPROVED Review Details
06/04/2025 RESIDENTIAL NEW DWELLING v.1 07/02/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0625-02831
Permit Status: Inspections
Permit Description: ADU
Total Outstanding Activity Conditions - 1
Date Name
06/26/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-0625-02831
Permit Status: Inspections
Permit Description: ADU
Date Description Comments
06/04/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0625-02831
Permite Description: ADU
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/21/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 9/21/26: add anchor bolts within 12" at the ends of each plate and space at 6' intervals. An anchor bolt is required within 12" of a splice on both sides, shot pins are required within 6" at each end of a sill plate. 2 shot pins are required per plate and shot pins shall be placed at 32" o.c. Maximum. Add nails to exterior sheathing at 6" o.c. Along edges/splices and 12" in the field, replace drywall screws at above framing Simpson hangers, add h25 clips at load bearing points, sister damage 2x4 stud at south wall.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0625-02831
Permit Description: ADU
Total Completed Inspections - 4
Date Description Inspector Results Comments
08/28/2026 COT - RSPL - Rough Soil Passed 8-28-26 OK to proceed shading is required
09/03/2026 COT - RSBU - Preslab Passed Passed
09/03/2026 COT - RSBU - Excavation/Rebar/Zoning Passed Passed
09/21/2026 COT - RSBU - Roof Nailing Passed 9/21/26: okay to dry-in roof.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
5849 ADU CORRECTIONS LETTER_V1.PDF DOCUMENTS VIEW
CONS-5849 S 6TH ADU PLAN SET V2_V2.PDF DOCUMENTS VIEW