Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0625-02831

Parcel: 138102220

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
09/21/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 9/21/26: add anchor bolts within 12" at the ends of each plate and space at 6' intervals. An anchor bolt is required within 12" of a splice on both sides, shot pins are required within 6" at each end of a sill plate. 2 shot pins are required per plate and shot pins shall be placed at 32" o.c. Maximum. Add nails to exterior sheathing at 6" o.c. Along edges/splices and 12" in the field, replace drywall screws at above framing Simpson hangers, add h25 clips at load bearing points, sister damage 2x4 stud at south wall.