Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address:
2421 N JORDAN DR
Address NEW:
2421 N JORDAN DR
Apply Date:
06/25/2023
Applicant:
Flor Sandoval
Description:
Bedroom Suite and Garage Addition

Permit Reviews

Permit Number - TC-RES-0623-06112
Permit Status: Complete
Permit Description: Bedroom Suite and Garage Addition
Start Date Submittal Complete Date Status  
06/28/2023 RESIDENTIAL NEW DWELLING v.1 07/13/2023 REQUIRES RESUBMIT Review Details
11/17/2023 RESIDENTIAL NEW DWELLING v.2 12/12/2023 REQUIRES RESUBMIT Review Details
02/27/2024 RESIDENTIAL NEW DWELLING v.3 03/28/2024 REQUIRES RESUBMIT Review Details
04/22/2024 RESTAMP - RESIDENTIAL v.1 04/22/2024 APPROVED Review Details
04/04/2024 RESIDENTIAL NEW DWELLING v.4 04/22/2024 APPROVED Review Details

Conditions

Permit Number - TC-RES-0623-06112
Permit Status: Complete
Permit Description: Bedroom Suite and Garage Addition
Date Description Comments
04/22/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0623-06112
Permite Description: Bedroom Suite and Garage Addition
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
09/17/2024 COT - RSBU - Preslab N/A Not Ready
02/19/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 2/19/25: wiring size not per plan at garage receptacles, properly secure Romex with 12" from box, grounding required at all metal boxes, seal all penetrations through vapor barrier and top plate, receptacle boxes at bathroom addition required at intermediate, boxes must be made up at intermediate inspection, registers must be blocked on three sides, BOCA plates required at plumbing pipes in bathrooms and secure all DWV vents.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0623-06112
Permit Description: Bedroom Suite and Garage Addition
Total Completed Inspections - 10

Documents

File Name Document Type  
_OWNER BUILDER AFFIDAVIT TC-RES-0623-06112_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-PLAN_SET_3_V4.PDF DOCUMENTS VIEW
DDO_24_28_DECISION.PDF SPECIAL APPLICATIONS VIEW
DDO_24_28_APPLICATION.PDF SPECIAL APPLICATIONS VIEW
DDO_24_28_NOTICE.PDF SPECIAL APPLICATIONS VIEW
DDO_24_28_PLAN SET.PDF SPECIAL APPLICATIONS VIEW