Permit: TC-RES-0623-05913
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
117 W CALLE GARCIA
Address NEW:
117 W CALLE GARCIA
Apply Date:
06/14/2023
Applicant:
Kristjan Laumets
Description:
Fire Damage Repair
Permit Reviews
Permit Number - TC-RES-0623-05913
Permit Status: Expired
Permit Description: Fire Damage Repair
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/13/2023 | RESIDENTIAL NEW DWELLING v.2 | 10/30/2023 | APPROVED |
| 06/15/2023 | RESIDENTIAL NEW DWELLING v.1 | 07/05/2023 | APPROVED |
| 10/11/2023 | RESIDENTIAL NEW DWELLING v.1 | 10/11/2023 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0623-05913
Permit Status: Expired
Permit Description: Fire Damage Repair
| Date | Description | Comments |
|---|---|---|
| 08/31/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Expired
Permit Number: TC-RES-0623-05913
Permite Description: Fire Damage Repair
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/03/2025 | COT - RSEL - Electrical Final | N/A | Not Ready | 01/03/25 The 3 GFCI breakers need to be square D, same as panel. Arc fault breakers breakers required throughout. Secure ground to the wall at panel. Change to connecting to irreversible clip. Missing water hammer arrestor, refrigerator and laundry. GFI receptacles needed throughout. Weather resistant receptacle needed outside. |
| 09/11/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Not Ready |
Completed Inspections
Permit Status: Expired
Permit Number: TC-RES-0623-05913
Permit Description: Fire Damage Repair
Total Completed Inspections - 9
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/07/2023 | COT - RSBU - Roof Nailing | Passed | ||
| 11/08/2024 | BULD - Electrical Clearance | Passed | Clearance for TEP INCR. 11/8/2024 | |
| 11/22/2024 | COT - BULD - SWG Clearance | Passed | 11/22/24 SWG clearence pass | |
| 01/03/2025 | COT - RSEL - Grounding/Bonding | Passed | ||
| 01/03/2025 | COT - RSPL - Gas Pressure Test | Passed | ||
| 01/09/2025 | COT - RSEL - Electrical Final | Passed | 01/09/25 Passed |
|
| 01/09/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 01/09/25 Passed |
|
| 01/09/2025 | COT - RSME - Mechanical Final | Passed | 01/09/25 Passed |
|
| 01/09/2025 | COT - RSPL - Plumbing Final | Passed | 01/09/25 Passed |