Permit: TC-RES-0526-02658
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
867 W CALLE DE LOS HIGOS
Address NEW:
867 W CALLE DE LOS HIGOS
Apply Date:
05/19/2026
Applicant:
Kevin OSBORN
Description:
Ramada with Outdoor Kitchen, Garage, Spa and Deck and Site Walls
Permit Reviews
Permit Number - TC-RES-0526-02658
Permit Status: Inspections
Permit Description: Ramada with Outdoor Kitchen, Garage, Spa and Deck and Site Walls
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/25/2026 | RESIDENTIAL ADD/ALT v.1 | 07/24/2026 | REQUIRES RESUBMIT |
| 07/28/2026 | RESIDENTIAL ADD/ALT v.2 | 07/30/2026 | APPROVED |
| 10/26/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/29/2026 | APPROVED |
| 09/24/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/28/2026 | APPROVED |
| 05/29/2026 | RESIDENTIAL ADD/ALT SIMPLE REVIEW v.1 | N/A | REQUIRES RESUBMIT |
| 07/30/2026 | ADMINISTRATIVE v.1 | 07/30/2026 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-RES-0526-02658
Permit Status: Inspections
Permit Description: Ramada with Outdoor Kitchen, Garage, Spa and Deck and Site Walls
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 07/09/2026 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 07/09/2026 | SPECIAL INSPECTION FOR SPECIAL MOMENT RESISTING STEEL FRAMES IS REQUIRED. |
Conditions
Permit Number - TC-RES-0526-02658
Permit Status: Inspections
Permit Description: Ramada with Outdoor Kitchen, Garage, Spa and Deck and Site Walls
| Date | Description | Comments |
|---|---|---|
| 07/30/2026 | Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 07/09/2026 | Masonry Inspection Report submittal review is required. | |
| 07/09/2026 | Post-Installed Anchor Inspection Report is required. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0526-02658
Permite Description: Ramada with Outdoor Kitchen, Garage, Spa and Deck and Site Walls
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2026 | COT - RSBU - Preslab | N/A | Partial Pass | 09/15/2026 Partial pass pending remaining balcony. Verified footings, bedroom addition and garage. Special inspection report currently not uploaded, verified epoxy at dowels. Okay to pour at own risk. |
| 10/20/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 10/20/26: have architect submit a letter to the city for review/approval showing vertical reinforcement spacing & size for CMU wall at garage lintel. |
| COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Scheduled |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0526-02658
Permit Description: Ramada with Outdoor Kitchen, Garage, Spa and Deck and Site Walls
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/26/2026 | COT - RSPL - Rough Soil | Passed | Passed | |
| 08/26/2026 | COT - RSPL - Gas Pressure Test | Passed | Passed CLEARANCE SWG | |
| 11/23/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 11/23/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |
Scheduled Inspections
Scheduled Inspections - TC-RES-0526-02658
Status: Inspections
Description: Ramada with Outdoor Kitchen, Garage, Spa and Deck and Site Walls
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 11/24/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Scheduled | |
| 11/24/2026 | COT - RSBU - Excavation/Rebar/Zoning | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.