Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
718 W 44TH ST
Address NEW:
718 W 44TH ST
Apply Date:
05/17/2026
Applicant:
David Garcia
Description:
Conversion of 432 square foot porch to indoor enclosed space.

Permit Reviews

Permit Number - TC-RES-0526-02585
Permit Status: Inspections
Permit Description: Conversion of 432 square foot porch to indoor enclosed space.
Start Date Submittal Complete Date Status  
06/24/2026 ADMINISTRATIVE v.2 N/A APPROVED Review Details
06/04/2026 ADMINISTRATIVE v.1 06/04/2026 REQUIRES RESUBMIT Review Details
05/19/2026 RESIDENTIAL ADD/ALT v.1 06/04/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0526-02585
Permit Status: Inspections
Permit Description: Conversion of 432 square foot porch to indoor enclosed space.
Date Description Comments
05/19/2026 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0526-02585
Permite Description: Conversion of 432 square foot porch to indoor enclosed space.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/05/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 10/5/26: interior plates must be pressure treated-shot pins may be used on interior plates- max spacing for shot pins is 32" o.c. And shot pins are required within 6" at the ends of each plate, anchor bolts are required within 12" at the beginning each plate & 2 anchors within 12" of each side of a sill plate splice. Anchor bolts shall be space no greater than at 6' intervals. Expose the footing at each corner of the house-footings shall be a minimum of 12".

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
OWNER_V1.PDF DOCUMENTS VIEW
CONS-718 W 44TH_V1.PDF DOCUMENTS VIEW