Permit: TC-RES-0525-02774
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
2800 N PARK AV
Address NEW:
2800 N PARK AV
Apply Date:
05/29/2025
Applicant:
Cardenio Pena
Description:
remove old 200 amp disconnect and meter socket. Install new disconnect and meter with new riser and feeds
Permit Reviews
Permit Number - TC-RES-0525-02774
Permit Status: Complete
Permit Description: remove old 200 amp disconnect and meter socket. Install new disconnect and meter with new riser and feeds
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/29/2025 | RESIDENTIAL SIMPLE REVIEW v.1 | 05/30/2025 | APPROVED |
Conditions
Permit Number - TC-RES-0525-02774
Permit Status: Complete
Permit Description: remove old 200 amp disconnect and meter socket. Install new disconnect and meter with new riser and feeds
| Date | Description | Comments |
|---|---|---|
| 05/29/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0525-02774
Permit Description: remove old 200 amp disconnect and meter socket. Install new disconnect and meter with new riser and feeds
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/23/2025 | BULD - Electrical Clearance | Passed | 6.23.25 Proper bonding and grounding verified, neutrals marked with white tape. Mast is sub 3ft no further bracing required. Ground rods 6ft apart. Water bonded, not gas at unit no gas bond req. Lugs torqued to spec with marks. Panel is properly secured. Clear to cut over. |
|
| 07/10/2025 | COT - RSEL - Electrical Final | Passed | ||
| 07/10/2025 | RSEL - Electrical Progress | Passed |