Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
8862 E BLUEFIELD ST
Apply Date:
05/24/2025
Applicant:
Donald Livingstone
Description:
Fire Damage Repair

Permit Reviews

Permit Number - TC-RES-0525-02720
Permit Status: Complete
Permit Description: Fire Damage Repair
Start Date Submittal Complete Date Status  
05/27/2025 RESIDENTIAL NEW DWELLING v.1 06/25/2025 APPROVED Review Details
08/06/2025 RESIDENTIAL NEW DWELLING REVISION v.1 08/21/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-0525-02720
Permit Status: Complete
Permit Description: Fire Damage Repair
Date Description Comments
05/27/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0525-02720
Permite Description: Fire Damage Repair
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
08/14/2025 COT - RSBU - Roof Nailing N/A Re-inspection required Roofing not secure through, h2.5 clips missing nails
10/09/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Not Ready no access for inspection
12/16/2025 COT - RSEL - Electrical Final N/A Re-inspection required See building final comments.
12/16/2025 COT - RSME - Mechanical Final N/A Re-inspection required 1. Secure thermostat wiring on the roof coming off liquid tite. Secure opening on liquid tite conduit. And secure T-stat wire laying non the roof.
2. Paint condensate line to prevent sun damage
3. Cover 4x12 opening under HVAC platform; might have been old vent.
4. HVAC platform appears to be sagging in the middle and will collect water.
12/16/2025 RSBU - Building Final N/A Re-inspection required 12/16/25
1. Missing carbon monoxide detector; and per R315.6 should receive primary power from building wiring.
2. Smoke detectors are not UL listed and are not interconnected. May use UL listed Wireless smoke detectors per R314.4.
3. Range is missing anti-tip bracket.
4. Dishwasher is missing water hammer arrestor.
5. Ice maker missing water hammer arrestor.
6. Main panel schedule missing
7. Garage entry door needs to be solid core and self closing.
8. Breakers need to be ARC faulted rated for living rooms, bedrooms, dens and similar areas.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0525-02720
Permit Description: Fire Damage Repair
Total Completed Inspections - 6

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-8826 E BLUEFIELD FIRE RESTORE_V2.PDF_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
OWNER BUILDER AFF_V1.PDF DOCUMENTS VIEW
CONS-8826 E BLUEFIELD FIRE RESTORE_V1.PDF DOCUMENTS VIEW