Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
5362 E 4TH ST
Address NEW:
5362 E 4TH ST
Apply Date:
05/15/2025
Applicant:
GGV Designs
Description:
Renovate SFR for code compliance for work without permit

Permit Reviews

Permit Number - TC-RES-0525-02582
Permit Status: Inspections
Permit Description: Renovate SFR for code compliance for work without permit
Start Date Submittal Complete Date Status  
02/18/2026 RESIDENTIAL NEW DWELLING v.3 03/05/2026 REQUIRES RESUBMIT Review Details
07/01/2025 RESIDENTIAL NEW DWELLING v.2 07/01/2025 REQUIRES RESUBMIT Review Details
05/19/2025 RESIDENTIAL NEW DWELLING v.1 06/20/2025 REQUIRES RESUBMIT Review Details
04/09/2026 RESIDENTIAL NEW DWELLING v.4 04/22/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0525-02582
Permit Status: Inspections
Permit Description: Renovate SFR for code compliance for work without permit
Date Description Comments
05/19/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0525-02582
Permite Description: Renovate SFR for code compliance for work without permit
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
10/26/2026 COT - RSBU - Roof Nailing N/A Re-inspection required 10/26/2026
Expose and dig footers at one location to verify foundation at addition (bedroom 8 & 9), see detail S1-3. Expose drywall at hallway at top and bottom to verify framing and roof assembly. Kitchen countertops should be GFCI protected. All 15A and 20A habitable rooms and hallway need AFCI protected breakers at Panel C. Secure AC condenser unit outside to pad.
10/26/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 10/26/2026
Expose and dig footers at one location to verify foundation at addition (bedroom 8 & 9), see detail S1-3. Expose drywall at hallway at top and bottom to verify framing and roof assembly. Kitchen countertops should be GFCI protected. All 15A and 20A habitable rooms and hallway need AFCI protected breakers at Panel C. Secure AC condenser unit outside to pad.
10/26/2026 COT - RSME - Mechanical Final N/A Re-inspection required 10/26/2026
Expose and dig footers at one location to verify foundation at addition (bedroom 8 & 9), see detail S1-3. Expose drywall at hallway at top and bottom to verify framing and roof assembly. Kitchen countertops should be GFCI protected. All 15A and 20A habitable rooms and hallway need AFCI protected breakers at Panel C. Secure AC condenser unit outside to pad.
10/26/2026 COT - RSEL - Electrical Final N/A Re-inspection required 10/26/2026
Expose and dig footers at one location to verify foundation at addition (bedroom 8 & 9), see detail S1-3. Expose drywall at hallway at top and bottom to verify framing and roof assembly. Kitchen countertops should be GFCI protected. All 15A and 20A habitable rooms and hallway need AFCI protected breakers at Panel C. Secure AC condenser unit outside to pad.
10/26/2026 COT - RSBU - Preslab N/A Re-inspection required 10/26/2026
Expose and dig footers at one location to verify foundation at addition (bedroom 8 & 9), see detail S1-3. Expose drywall at hallway at top and bottom to verify framing and roof assembly. Kitchen countertops should be GFCI protected. All 15A and 20A habitable rooms and hallway need AFCI protected breakers at Panel C. Secure AC condenser unit outside to pad.
10/26/2026 RSBU - Building Final N/A Re-inspection required 10/26/2026
Expose and dig footers at one location to verify foundation at addition (bedroom 8 & 9), see detail S1-3. Expose drywall at hallway at top and bottom to verify framing and roof assembly. Kitchen countertops should be GFCI protected. All 15A and 20A habitable rooms and hallway need AFCI protected breakers at Panel C. Secure AC condenser unit outside to pad.
10/26/2026 COT - RSPL - Plumbing Final N/A Re-inspection required 10/26/2026
Expose and dig footers at one location to verify foundation at addition (bedroom 8 & 9), see detail S1-3. Expose drywall at hallway at top and bottom to verify framing and roof assembly. Kitchen countertops should be GFCI protected. All 15A and 20A habitable rooms and hallway need AFCI protected breakers at Panel C. Secure AC condenser unit outside to pad.
10/26/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 10/26/2026
Expose and dig footers at one location to verify foundation at addition (bedroom 8 & 9), see detail S1-3. Expose drywall at hallway at top and bottom to verify framing and roof assembly. Kitchen countertops should be GFCI protected. All 15A and 20A habitable rooms and hallway need AFCI protected breakers at Panel C. Secure AC condenser unit outside to pad.