Permit: TC-RES-0525-02495
Permit Details
Status:
Withdrawn
Type:
Residential Building - One or Two Family
Address:
6035 E BAKER ST
Address NEW:
6035 E BAKER ST
Apply Date:
05/09/2025
Applicant:
Kody Landals
Description:
Fabricated Steel Metal Building Onsite Fabricated Steel Metal Building $24,800.00 Build onto current concrete pad the following steel structure: Length x Width x Height or sqft (Final Designs to be done) 800sqft Roof Panel Profile: PBR Panel 26G Included Door: 3070 Walkdoor w/ Lever Lock (steel or fiberglass pedestrian door - 36'' Wide) Framed Openings: One (1) 10'x10' opening for Standard Roll Up door Four (4) 3x3 Standard Windows Eave Height Front: 12 Eave Height Rear: 12 Wind Speed Warranty: 115 MPH -4 3x3 Windows Prodex 10mm (R17) Metal Building Insulation $8,220.00 R17 Insulation + Radiant Barrier + Vapor Barrier + Air Barrier all in one product. Single solution for heat, cold and condesation. Reflective reinforced foil on each side of 5mm (.4 inch) closed-cell polyethylene foam center
Permit Reviews
Permit Number - TC-RES-0525-02495
Permit Status: Withdrawn
Permit Description: Fabricated Steel Metal Building
Onsite Fabricated Steel Metal Building $24,800.00
Build onto current concrete pad the following steel structure:
Length x Width x Height or sqft (Final Designs to be done)
800sqft
Roof Panel Profile: PBR Panel 26G
Included Door:
3070 Walkdoor w/ Lever Lock (steel or fiberglass pedestrian door - 36'' Wide)
Framed Openings:
One (1) 10'x10' opening for Standard Roll Up door
Four (4) 3x3 Standard Windows
Eave Height Front: 12
Eave Height Rear: 12
Wind Speed Warranty: 115 MPH
-4 3x3 Windows
Prodex 10mm (R17) Metal Building Insulation $8,220.00
R17 Insulation + Radiant Barrier + Vapor Barrier + Air Barrier all in one product.
Single solution for heat, cold and condesation.
Reflective reinforced foil on each side of 5mm (.4 inch) closed-cell polyethylene foam center
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/19/2025 | RESIDENTIAL NEW DWELLING v.2 | 06/19/2025 | REQUIRES RESUBMIT |
| 05/13/2025 | RESIDENTIAL NEW DWELLING v.1 | 05/14/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-RES-0525-02495
Permit Status: Withdrawn
Permit Description: Fabricated Steel Metal Building
Onsite Fabricated Steel Metal Building $24,800.00
Build onto current concrete pad the following steel structure:
Length x Width x Height or sqft (Final Designs to be done)
800sqft
Roof Panel Profile: PBR Panel 26G
Included Door:
3070 Walkdoor w/ Lever Lock (steel or fiberglass pedestrian door - 36'' Wide)
Framed Openings:
One (1) 10'x10' opening for Standard Roll Up door
Four (4) 3x3 Standard Windows
Eave Height Front: 12
Eave Height Rear: 12
Wind Speed Warranty: 115 MPH
-4 3x3 Windows
Prodex 10mm (R17) Metal Building Insulation $8,220.00
R17 Insulation + Radiant Barrier + Vapor Barrier + Air Barrier all in one product.
Single solution for heat, cold and condesation.
Reflective reinforced foil on each side of 5mm (.4 inch) closed-cell polyethylene foam center
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/13/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |