Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
05/03/2024
Applicant:
Terry Darr
Description:
SFR

Permit Reviews

Permit Number - TC-RES-0524-02709
Permit Status: Issued
Permit Description: SFR
Start Date Submittal Complete Date Status  
05/13/2024 RESIDENTIAL NEW DWELLING v.1 06/11/2024 REQUIRES RESUBMIT Review Details
09/19/2024 RESIDENTIAL NEW DWELLING v.2 10/21/2024 APPROVED Review Details
05/13/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 05/15/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0524-02709
Permit Status: Issued
Permit Description: SFR
Total Outstanding Activity Conditions - 1
Date Name
09/25/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Conditions

Permit Number - TC-RES-0524-02709
Permit Status: Issued
Permit Description: SFR
Date Description Comments
11/06/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
05/23/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-RES-0524-02709
Permite Description: SFR
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
11/04/2024 COT - RSPL - Sewer N/A Partial Pass 11/4/24: plumbing underground per plans and under test ok to proceed. Pending sewer connection.
12/11/2024 COT - RSPL - Yard Water Line N/A Re-inspection required Missing backfill material, rocks need to be removed from trench per P2604.1
07/18/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 7.18.25
No plans on site
Stud shoes or sister studs required at per notched areas in south bathroom
DWV not under test
DWV not secured properly
Bang plate at dryer vent
Fire blocking required at south ceiling area
Showers not under test
Seal penetrations at kitchen vent
Add securing straps every 10ft at kitchen vent
Can note use drywall screws at S connector securing kitchen duct
Secure return air at south hall
Seal penetrations throughout
STOPPED INSPECTION MORE ITEMS MAY BE PRESENT
07/18/2025 COT - RSEL - Grounding/Bonding N/A Re-inspection required 7.18.25
No plans on site
07/18/2025 BULD - Electrical Clearance N/A Re-inspection required 7.18.25
No plans on site

Completed Inspections

Permit Status: Issued
Permit Number: TC-RES-0524-02709
Permit Description: SFR
Total Completed Inspections - 11
Date Description Inspector Results Comments
11/04/2024 COT - RSPL - Rough Soil Passed 11/4/24: plumbing underground per plans and under test ok to proceed.
11/12/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
11/12/2024 COT - RSBU - Preslab Passed
11/12/2024 COT - RSEL - Electrical Underground Passed
11/12/2024 COT - RSPL - Sewer Passed
12/16/2024 COT - RSPL - Yard Water Line Passed 12/16/24 corrections made ok to backfill
05/02/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Ok to cover exterior walls.
05/02/2025 COT - RSBU - Roof Nailing Passed Ensure Southwest portion of structure is completed. When,completed, OK to dry-in roof system.
07/25/2025 COT - RSEL - Grounding/Bonding Passed
08/22/2025 COT - RSBU - Interior Shear Bracing Passed OK for intermediate inspections
11/18/2025 BULD - Electrical Clearance Passed 11.18.25
Approved for ECO clearance to TEP

Documents

File Name Document Type  
TC-RES-0524-02709-M1_V1.PDF DOCUMENTS VIEW
TC-RES-0524-02709-MCALCS.PDF_V1.PDF DOCUMENTS VIEW
TC-RES-0524-02709-MEMO2_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
TC-RES-0524-02709-D2_V1.PDF DOCUMENTS VIEW
TC-RES-0524-02709-SC_V1.PDF DOCUMENTS VIEW
TC-RES-0524-02709-SR_V1.PDF DOCUMENTS VIEW